Your browser doesn't support javascript.
loading
Determination of cotinine and 3-hydroxynicotinine in human serum by liquid chromatography-tandem mass spectrometry and its application.
Wang, Da-Guang; Du, Ke-He; Shao, Li-Jun; Ma, Shi-Qiao; Yang, Xiao-Feng; Liu, Tian-Yi; Liu, Qian; Wang, Meng; Liu, Hong-Jun; Wu, Yi-Qun.
Affiliation
  • Wang DG; Aviation General Hospital Clinical Laboratory, Beijing, China.
  • Du KH; Department of Analytical Services of Iphase Pharma Services (Think Tank Research Center for Health Development Laboratory), Beijing, China.
  • Shao LJ; Department of Analytical Services of Iphase Pharma Services (Think Tank Research Center for Health Development Laboratory), Beijing, China.
  • Ma SQ; Department of Analytical Services of Iphase Pharma Services (Think Tank Research Center for Health Development Laboratory), Beijing, China.
  • Yang XF; Beijing Hospital Laboratory, National Center for Gerontology, Beijing, China.
  • Liu TY; Beijing Hospital Laboratory, National Center for Gerontology, Beijing, China.
  • Liu Q; Beijing Hospital Laboratory, National Center for Gerontology, Beijing, China.
  • Wang M; Beijing Hospital Laboratory, National Center for Gerontology, Beijing, China.
  • Liu HJ; Department of Analytical Services of Iphase Pharma Services (Think Tank Research Center for Health Development Laboratory), Beijing, China.
  • Wu YQ; Department of Analytical Services of Iphase Pharma Services (Think Tank Research Center for Health Development Laboratory), Beijing, China.
Medicine (Baltimore) ; 103(23): e38339, 2024 Jun 07.
Article in En | MEDLINE | ID: mdl-38847666
ABSTRACT
In this study, we developed a method for determining cotinine and 3-hydroxycotinine in human serum and established a methodology for an in-depth study of tobacco exposure and health. After the proteins in the human serum samples were precipitated with acetonitrile, they were separated on a ZORBAX SB-Phenyl column with a mobile phase of methanol encompassing 0.3% formic acid-water encompassing 0.15% formic acid. The measurement was performed on an API5500 triple quadrupole mass spectrometer in the multiple reaction monitoring mode. Cotinine, 3-hydroxycotinine, and cotinine-d3 isotope internal standards were held for 2.56 minutes, 1.58 minutes, and 2.56 minutes, respectively. In serum, the linear range was 0.05 to 500 ng·mL-1 for cotinine and 0.50 to 1250 ng·mL-1 for 3-hydroxycotinine. The lower limit of quantification (LLOQ) was 0.05 ng·mL-1 and 0.5 ng·mL-1 for cotinine and 3-hydroxycotinine, respectively. The intra-day and inter-day relative standard deviations were <11%, and the relative errors were within ±â€…7%. Moreover, the mean extraction recoveries of cotinine and 3-hydroxycotinine were 98.54% and 100.24%, respectively. This method is suitable for the rapid determination of cotinine and 3-hydroxycotinine in human serum because of its rapidity, sensitivity, strong specificity, and high reproducibility. The detection of cotinine levels in human serum allows for the identification of the cutoff value, providing a basis for differentiation between smoking and nonsmoking populations.
Subject(s)

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Cotinine / Tandem Mass Spectrometry Limits: Humans Language: En Journal: Medicine (Baltimore) Year: 2024 Type: Article Affiliation country: China

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Cotinine / Tandem Mass Spectrometry Limits: Humans Language: En Journal: Medicine (Baltimore) Year: 2024 Type: Article Affiliation country: China