Your browser doesn't support javascript.
loading
Enhancing gas chromatography-mass spectrometry resolution and pure analyte discovery using intra-chromatogram elution profile matching.
Cain, Caitlin N; Synovec, Robert E.
Affiliation
  • Cain CN; Department of Chemistry, University of Washington, Box 351700, Seattle, WA, 98195, USA.
  • Synovec RE; Department of Chemistry, University of Washington, Box 351700, Seattle, WA, 98195, USA. Electronic address: synovec@chem.washington.edu.
Talanta ; 278: 126453, 2024 Oct 01.
Article in En | MEDLINE | ID: mdl-38908137
ABSTRACT
Chemometric decomposition methods like multivariate curve resolution-alternating least squares (MCR-ALS) are often employed in gas chromatography-mass spectrometry (GC-MS) to improve analyte identification and quantitation. However, these methods can perform poorly for analytes with a low chromatographic resolution (Rs) and a high degree of spectral contamination from noise and background interferences. Thus, we propose a novel computational algorithm, termed mzCompare, to improve analyte identification and quantitation when coupled to MCR-ALS. The mzCompare method utilizes an underlying requirement that the retention time and peak shape between mass channels (m/z) of the same analyte should be similar. By discovering the selective m/z for a given analyte in a chromatogram, a pure elution profile can be generated and used as an equality constraint in MCR-ALS. The performance of the mzCompare methodology is demonstrated with both experimental and simulated chromatograms. Experimentally, unresolved analytes with a Rs as low as 0.05 could be confidently identified with mzCompare assisted MCR-ALS. Furthermore, application of the mzCompare algorithm to a complex aerospace fuel resulted in the discovery of 335 analytes, a 44 % increase compared to conventional peak detection methods. GC-MS simulations of target-interferent analyte pairs demonstrated that the performance of MCR-ALS deteriorated below a Rs of ∼0.25. However, mzCompare assisted MCR-ALS showed excellent identification and acceptable quantitative accuracy at a Rs of ∼0.02. These results show that the mzCompare algorithm can help analysts overcome modeling ambiguities resulting from the chemometric multiplex disadvantage.
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Language: En Journal: Talanta Year: 2024 Type: Article Affiliation country: United States

Full text: 1 Collection: 01-internacional Database: MEDLINE Language: En Journal: Talanta Year: 2024 Type: Article Affiliation country: United States