Your browser doesn't support javascript.
loading
Sonoanatomy of the Finger Synovio-Entheseal Complexes.
Naredo, Esperanza; Uson, Jacqueline; Olivas-Vergara, Otto; Guillén-Astete, Carlos; González Del Pozo, Pablo; Mérida-Velasco, José Ramón; Murillo-González, Jorge.
Affiliation
  • Naredo E; Department of Rheumatology and Joint and Bone Research Unit, Hospital Universitario Fundación Jiménez Díaz, Instituto de Investigación Sanitaria Fundación Jiménez Díaz (IIS-FJD, UAM), Madrid, Spain; Faculty of Medicine, Autonomous University of Madrid, Madrid, Spain. Electronic address: enaredo@ser.
  • Uson J; Department of Rheumatology, Hospital Universitario de Móstoles, Madrid, Spain; Faculty of Medicine, Rey Juan Carlos University of Madrid, Madrid, Spain.
  • Olivas-Vergara O; Department of Rheumatology and Joint and Bone Research Unit, Hospital Universitario Fundación Jiménez Díaz, Instituto de Investigación Sanitaria Fundación Jiménez Díaz (IIS-FJD, UAM), Madrid, Spain; Faculty of Medicine, Autonomous University of Madrid, Madrid, Spain.
  • Guillén-Astete C; Department of Rheumatology, Hospital Universitario Ramón y Cajal, Madrid, Spain; Faculty of Biomedical and Health Sciences, Universidad Europea of Madrid, Madrid, Spain.
  • González Del Pozo P; Department of Rheumatology and Joint and Bone Research Unit, Hospital Universitario Fundación Jiménez Díaz, Instituto de Investigación Sanitaria Fundación Jiménez Díaz (IIS-FJD, UAM), Madrid, Spain; Department of Rheumatology, Hospital Universitario Central de Asturias, Oviedo, Spain.
  • Mérida-Velasco JR; Department of Anatomy and Embryology, Faculty of Medicine, Complutense University of Madrid, Madrid, Spain.
  • Murillo-González J; Department of Anatomy and Embryology, Faculty of Medicine, Complutense University of Madrid, Madrid, Spain.
Ultrasound Med Biol ; 2024 Sep 16.
Article in En | MEDLINE | ID: mdl-39289117
ABSTRACT

OBJECTIVES:

The objectives of this ultrasound and anatomical study were (1) To evaluate the reliability of ultrasound identification of the enthesis of the central slip of the extensor digitorum tendon (CSET) using cadaver specimens; (2) To assess the concordance of the measurement of the CSET thickness by ultrasound and gross anatomy; (3) To evaluate the variation in ultrasound identification of the CSET enthesis in a cadaveric experimental model of PIP synovitis.

METHODS:

Four rheumatologist ultrasonographers blindly and independently measured by ultrasound the CSET enthesis thickness in the second to fifth fingers of 8 hands from fresh-frozen human cadavers in two rounds. These fingers were dissected and the thickness of the CSET measured by the anatomist. In addition, an artificial synovitis was created in the proximal interphalangeal (PIP) joints of a different cadaveric hand. The ultrasonographic CSET enthesis thickness was measured by the four investigators before and after intra-articular ultrasound guided injection of material.

RESULTS:

Intra- and inter-observer reliability of CSET enthesis thickness measurement were good to excellent (ICC 0.93 for intra-observer agreement and 0.89-0.92 for inter-observer agreement). Ultrasound measurements were consistent and only slightly smaller than the anatomical ones (µ = -0.039 mm). The differences between the measurements of CSET enthesis thickness before and after the synovitis model were not statistically significant.

CONCLUSION:

Ultrasound demonstrated high multiobserver reliability and agreement with gross anatomy in identifying the CSET enthesis and discriminated it from the capsular tissue of the PIP. Furthermore, an experimental model of PIP synovitis did not interfere with its identification.