Your browser doesn't support javascript.
loading
The impact of image reconstruction settings on 18F-FDG PET radiomic features: multi-scanner phantom and patient studies.
Shiri, Isaac; Rahmim, Arman; Ghaffarian, Pardis; Geramifar, Parham; Abdollahi, Hamid; Bitarafan-Rajabi, Ahmad.
Afiliación
  • Shiri I; Department of Medical Physics, School of Medicine, Iran University of Medical Sciences, Junction of Shahid Hemmat and Shahid Chamran Expressways, Tehran, Iran.
  • Rahmim A; Department of Radiology, Johns Hopkins University, Baltimore, MD, 21287, USA.
  • Ghaffarian P; Department of Electrical and Computer Engineering, Johns Hopkins University, Baltimore, MD, 21218, USA.
  • Geramifar P; Chronic Respiratory Diseases Research Center, National Research Institute of Tuberculosis and Lung Diseases (NRITLD), Shahid Beheshti University of Medical Sciences, Tehran, Iran.
  • Abdollahi H; PET/CT and Cyclotron Center, Masih Daneshvari Hospital, Shahid Beheshti University of Medical Sciences, Tehran, Iran.
  • Bitarafan-Rajabi A; Research Center for Nuclear Medicine, Shariati Hospital, Tehran University of Medical Sciences, Tehran, Iran.
Eur Radiol ; 27(11): 4498-4509, 2017 Nov.
Article en En | MEDLINE | ID: mdl-28567548
ABSTRACT

OBJECTIVES:

The purpose of this study was to investigate the robustness of different PET/CT image radiomic features over a wide range of different reconstruction settings.

METHODS:

Phantom and patient studies were conducted, including two PET/CT scanners. Different reconstruction algorithms and parameters including number of sub-iterations, number of subsets, full width at half maximum (FWHM) of Gaussian filter, scan time per bed position and matrix size were studied. Lesions were delineated and one hundred radiomic features were extracted. All radiomics features were categorized based on coefficient of variation (COV).

RESULTS:

Forty seven percent features showed COV ≤ 5% and 10% of which showed COV > 20%. All geometry based, 44% and 41% of intensity based and texture based features were found as robust respectively. In regard to matrix size, 56% and 6% of all features were found non-robust (COV > 20%) and robust (COV ≤ 5%) respectively.

CONCLUSIONS:

Variability and robustness of PET/CT image radiomics in advanced reconstruction settings is feature-dependent, and different settings have different effects on different features. Radiomic features with low COV can be considered as good candidates for reproducible tumour quantification in multi-center studies. KEY POINTS • PET/CT image radiomics is a quantitative approach assessing different aspects of tumour uptake. • Radiomic features robustness is an important issue over different image reconstruction settings. • Variability and robustness of PET/CT image radiomics in advanced reconstruction settings is feature-dependent. • Robust radiomic features can be considered as good candidates for tumour quantification.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Procesamiento de Imagen Asistido por Computador / Fantasmas de Imagen / Fluorodesoxiglucosa F18 / Tomografía Computarizada por Tomografía de Emisión de Positrones / Neoplasias de Cabeza y Cuello / Neoplasias Hepáticas Tipo de estudio: Clinical_trials Límite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Revista: Eur Radiol Asunto de la revista: RADIOLOGIA Año: 2017 Tipo del documento: Article País de afiliación: Irán

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Procesamiento de Imagen Asistido por Computador / Fantasmas de Imagen / Fluorodesoxiglucosa F18 / Tomografía Computarizada por Tomografía de Emisión de Positrones / Neoplasias de Cabeza y Cuello / Neoplasias Hepáticas Tipo de estudio: Clinical_trials Límite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Revista: Eur Radiol Asunto de la revista: RADIOLOGIA Año: 2017 Tipo del documento: Article País de afiliación: Irán