Your browser doesn't support javascript.
loading
Validation of a new inertial measurement unit system based on different dynamic movements for future in-field applications.
Bessone, Veronica; Höschele, Nadja; Schwirtz, Ansgar; Seiberl, Wolfgang.
Afiliación
  • Bessone V; Department of Biomechanics in Sports, Faculty of Sport and Health Sciences, Technical University of Munich, Munich, Germany.
  • Höschele N; Department of Biomechanics in Sports, Faculty of Sport and Health Sciences, Technical University of Munich, Munich, Germany.
  • Schwirtz A; Department of Biomechanics in Sports, Faculty of Sport and Health Sciences, Technical University of Munich, Munich, Germany.
  • Seiberl W; Department of Biomechanics in Sports, Faculty of Sport and Health Sciences, Technical University of Munich, Munich, Germany.
Sports Biomech ; 21(6): 685-700, 2022 Jul.
Article en En | MEDLINE | ID: mdl-31718486
ABSTRACT
Using inertial measurement units (IMUs) in monitoring and analysing sport movements has become popular in sports research since it avoids the laboratory limitation. However, the accuracy of modern IMU-systems (hardware combined with software) needs to be validated using gold-standard systems as baseline. In this study, we investigated the feasibility of the aktos-t IMU-system for in-field biomechanical research by comparing its outputs in various tasks (repetitive movements, gait and jumping) undertaken by 14 participants, with those of an optoelectronic system. The results showed that the accuracy of aktos-t varies according to the task performed. The accuracy of pelvis, hip and knee joints ranged between acceptable (root mean squared error (RMSE) < 5°) and tolerable (RMSE < 10°) in gait, while the upper limb joints showed inaccuracy (RMSE > 10°) and imprecision (coefficient of repeatability > 10°) during the repetitive movement test. Jump impact appeared not to influence the IMU outcomes (p > 0.05). The main sources of error could be related to the IMU-alignment during the reference T-pose. Finally, the study provides researchers the means for evaluating the accuracy of aktos-t (hardware, software and biomechanical model) as sufficiently precise for its application in their in-field investigations.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Deportes / Monitoreo Ambulatorio / Movimiento Tipo de estudio: Prognostic_studies Límite: Humans Idioma: En Revista: Sports Biomech Asunto de la revista: MEDICINA ESPORTIVA Año: 2022 Tipo del documento: Article País de afiliación: Alemania

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Deportes / Monitoreo Ambulatorio / Movimiento Tipo de estudio: Prognostic_studies Límite: Humans Idioma: En Revista: Sports Biomech Asunto de la revista: MEDICINA ESPORTIVA Año: 2022 Tipo del documento: Article País de afiliación: Alemania