Development and Validation of Fast and Sensitive RP-HPLC Stability-Indicating Method for Quantification of Piroxicam in Bulk Drug.
Chauhan, Vikas; Grover, Parul; Bhardwaj, Monika; Kumar, Sandeep; Nagarajan, K.
Afiliación
  • Chauhan V; KIET School of Pharmacy, KIET Group of Institutions, Delhi-NCR, Ghaziabad 201206, India.
  • Grover P; KIET School of Pharmacy, KIET Group of Institutions, Delhi-NCR, Ghaziabad 201206, India.
  • Bhardwaj M; Natural Product and Medicinal Chemistry Division, Indian Institute of Integrative Medicine (CSIR-IIIM), Jammu 180001, India.
  • Kumar S; Nims Institute of Pharmacy, Nims University Rajasthan, Jaipur Delhi Highway, Jaipur, Rajasthan, 303121, India.
  • Nagarajan K; KIET School of Pharmacy, KIET Group of Institutions, Delhi-NCR, Ghaziabad 201206, India.
J Chromatogr Sci ; 2024 May 04.
Article en En | MEDLINE | ID: mdl-38704244
ABSTRACT
A simple, rapid, sensitive, and cost-effective green solvent-assisted reverse-phase high-performance liquid chromatographic technique, coupled with a photodiode array detector, was developed and validated for the estimation of piroxicam (PRXM). The chromatographic separation was achieved by using a C-18 (250 × 4.6) mm, 5-µm stationary phase and a mobile phase consisting of methanol and 0.1% ortho-phosphoric acid in water in a ratio of (8020) v/v at a flow rate of 1 ml/min. The detection was carried out at a wavelength of 254 nm with a constant injection volume of 10 µL throughout the analysis. The calibration curve was observed to be linear over the optimum concentration range of 50-300 µg mL-1, with an R2 value of 0.9995. The developed method was validated as per the International Council for Harmonisation (ICH) Q2 (R1) guideline. Various parameters like selectivity/specificity, accuracy/recovery, linearity, precision, detection limit, quantitation limit, robustness and stability of analyte in solution were performed for the method validation. The PRXM was evaluated under stressed conditions, including acidic, basic, oxidative, thermal and photolytic, as per ICH Q1 (R2) guidelines. Significant degradation was observed in acidic and basic degradation conditions. Conversely, the drug substance showed stability when exposed to oxidative, photolytic and thermal degradation conditions.