Myocardial performance index in female rats with myocardial infarction: relationship with ventricular function parameters by Doppler echocardiography.
J Am Soc Echocardiogr
; 18(5): 454-60, 2005 May.
Article
em En
| MEDLINE
| ID: mdl-15891755
BACKGROUND: The aim of the study was to analyze the myocardial performance index (MPI), its relationship with the standard variables of systolic and diastolic functions, and the influence of time intervals in an experimental model of female rats with myocardial infarction (MI). METHODS: Forty-one Wistar female rats were submitted to surgery to induce MI. Six weeks later, Doppler echocardiography was performed to assess infarct size (IS,%), fractional area change (FAC,%), ejection fraction biplane Simpson (EF), E/A ratio of mitral inflow, MPI and its time intervals: isovolumetric contraction (IVCT, ms) and relaxation (IVRT, ms) times, and ejection time (ET, ms); MPI = IVCT + IVRT/ET. RESULTS: EF and FAC were progressively lower in rats with small, medium and large-size MI ( P < .001). E/A ratio was higher only in rats with large-size MI (6.25 +/- 2.69; P < .001). MPI was not different between control rats and small-size MI (0.37 +/- 0.03 vs 0.34 +/- 0.06, P = .87), but different between large and medium-size MI (0.69 +/- 0.08 vs 0.47 +/- 0.07; P < .001) and between these two compared to small-size MI. MPI correlated with IS (r = 0.85; P < .001), EF (r = -0.86; P < .001), FAC (r = -0.77; P < .001) and E/A ratio (r = 0.77; P < .001, non-linear). IVCT was longer in large size MI compared to medium-size MI (31.87 +/- 7.99 vs 15.92 +/- 5.88; P < .001) and correlated with IS (r = 0.85; P < .001) and MPI (r = 0.92; P < .001). ET was shorter only in large-size MI (81.07 +/- 7.23; P < .001), and correlated with IS (r = -0.70; P < .001) and MPI (r = -0.85; P < .001). IVRT was shorter only in large-size compared to medium-size MI (24.40 +/- 5.38 vs 29.69 +/- 5.92; P < .037), had borderline correlation with MPI (r = 0.34; P = .0534) and no correlation with IS (r = 0.26; p = 0.144). CONCLUSIONS: The MPI increased with IS, correlated inversely with systolic function parameters and had a non-linear relationship with diastolic function. These changes were due to the increase of IVCT and a decrease of ET, without significant influence of IVRT.
Buscar no Google
Coleções:
01-internacional
Base de dados:
MEDLINE
Assunto principal:
Ecocardiografia Doppler
/
Infarto do Miocárdio
Tipo de estudo:
Prognostic_studies
Limite:
Animals
Idioma:
En
Revista:
J Am Soc Echocardiogr
Assunto da revista:
DIAGNOSTICO POR IMAGEM
Ano de publicação:
2005
Tipo de documento:
Article
País de afiliação:
Brasil