Hypoxaemia during open-airway apnoea: a computational modelling analysis.
McNamara, M J; Hardman, J G.
Afiliação
  • McNamara MJ; Department of Intensive Care, Gold Coast Hospital, Southport, Queensland 4215, Australia.
Anaesthesia ; 60(8): 741-6, 2005 Aug.
Article em En | MEDLINE | ID: mdl-16029221
ABSTRACT
Hypoxaemia during open-airway apnoea, e.g. during brainstem death testing, may cause organ damage. The effect of ambient oxygen fraction on the extent of hypoxaemia has not been established. We validated the Nottingham Physiology Simulator in this context by reproducing the methodologies and results of four published clinical studies. We then used the simulator to examine the effects of different ambient oxygen fractions (0.21-1.0) and shunt fractions (1-30% of cardiac output) during apnoea. Increasing ambient oxygen fraction from 0.9 to 1.0 more than doubled the time to haemoglobin desaturation at all shunt fractions, and extended apnoea longer than when the ambient oxygen fraction was increased from 0.21 to 0.9. When ambient oxygen fraction and shunt fraction were large, arterial oxygen tension transiently increased during apnoea. A very high ambient oxygen fraction and a patent airway are likely to delay dangerous hypoxaemia during apnoea.
Assuntos
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Apneia / Simulação por Computador / Hipóxia / Modelos Biológicos Tipo de estudo: Prognostic_studies Limite: Humans Idioma: En Revista: Anaesthesia Ano de publicação: 2005 Tipo de documento: Article País de afiliação: Austrália
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Apneia / Simulação por Computador / Hipóxia / Modelos Biológicos Tipo de estudo: Prognostic_studies Limite: Humans Idioma: En Revista: Anaesthesia Ano de publicação: 2005 Tipo de documento: Article País de afiliação: Austrália