Retropubic hematoma after transobturator sling procedure.
Rajan, Sujatha; Kohli, Neeraj.
Afiliação
  • Rajan S; Division of Urogynecology and Pelvic Reconstructive Surgery, Brigham and Women's Hospital, Harvard Medical School, Boston, Massachusetts 02115, USA. srajan@partners.org
Obstet Gynecol ; 106(5 Pt 2): 1199-202, 2005 Nov.
Article em En | MEDLINE | ID: mdl-16260571
ABSTRACT

BACKGROUND:

The transobturator tape procedure is one of the newer minimally invasive sling procedures used for the surgical treatment of genuine stress urinary incontinence. CASES Two cases of retropubic hematomas following transobturator tape procedure are reported. One patient was managed conservatively and did not require reoperation, and the other patient required computed tomography-guided drainage of the hematoma. In both cases the patients' hematomas resolved, and they remained continent 3-6 months after surgery.

CONCLUSION:

The transobturator tape procedure is a minimally invasive alternative to the tension-free vaginal tape operation for stress urinary incontinence, but it may be associated with vascular complications.
Assuntos
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Procedimentos Cirúrgicos Urogenitais / Incontinência Urinária por Estresse / Procedimentos Cirúrgicos Minimamente Invasivos / Hematoma Limite: Female / Humans / Middle aged Idioma: En Revista: Obstet Gynecol Ano de publicação: 2005 Tipo de documento: Article País de afiliação: Estados Unidos
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Procedimentos Cirúrgicos Urogenitais / Incontinência Urinária por Estresse / Procedimentos Cirúrgicos Minimamente Invasivos / Hematoma Limite: Female / Humans / Middle aged Idioma: En Revista: Obstet Gynecol Ano de publicação: 2005 Tipo de documento: Article País de afiliação: Estados Unidos