Measuring seasonal variations of moisture in a landfill with the partitioning gas tracer test.
Waste Manag
; 26(4): 344-55, 2006.
Article
em En
| MEDLINE
| ID: mdl-16458495
Seven pilot-scale partitioning gas tracer tests (PGTTs) were conducted to assess the accuracy and reproducibility of this method for measuring water in municipal solid waste landfills. Tests were conducted in the same location over a 12-month period, and measured moisture conditions ranged from possible dry waste to refuse with a moisture content of 24.7%. The final moisture content of 24.7% was in reasonable agreement with gravimetric measurements of excavated refuse, where the moisture content was 26.5+/-6.0 CI%. Laboratory tests were used to assess the utility of the PGTT for measuring water in small pores, water sorbed to solid surfaces, and the influence of dry waste on PGTTs. These experiments indicated that when refuse surfaces are not completely solvated with water, PGTTs may produce misleading results (negative estimates) of water saturation and moisture content.
Buscar no Google
Coleções:
01-internacional
Base de dados:
MEDLINE
Assunto principal:
Água
/
Eliminação de Resíduos
Tipo de estudo:
Evaluation_studies
Idioma:
En
Revista:
Waste Manag
Assunto da revista:
SAUDE AMBIENTAL
/
TOXICOLOGIA
Ano de publicação:
2006
Tipo de documento:
Article
País de afiliação:
Estados Unidos