Early adverse events as predictors of 1-year mortality during mechanical circulatory support.
Genovese, Elizabeth A; Dew, Mary Amanda; Teuteberg, Jeffrey J; Simon, Marc A; Bhama, Jay K; Bermudez, Christian A; Lockard, Kathleen L; Winowich, Steve; Kormos, Robert L.
Afiliação
  • Genovese EA; Artificial Heart Program, University of Pittsburgh Medical Center, Pittsburgh, Pennsylvania, USA.
J Heart Lung Transplant ; 29(9): 981-8, 2010 Sep.
Article em En | MEDLINE | ID: mdl-20580265
ABSTRACT

BACKGROUND:

Ventricular assist devices (VADs) provide effective treatment for end-stage heart failure; however, most patients experience > or =1 major adverse events (AEs) while on VAD support. Although early, non-fatal AEs may increase the risk of later death during VAD support, this relationship has not been established. Therefore, we sought to determine the impact on 1-year mortality of AEs occurring during the first 60 days of VAD support.

METHODS:

A retrospective analysis was performed using prospectively collected data from a single-site database for patients aged > or =18 years receiving left ventricular or biventricular support during 1996 to 2008 and who survived >60 days on VAD support. Fourteen major classes of AEs occurring during this 60-day period were examined. One-year survival rates of patients with and without each major AE were compared.

RESULTS:

The study included 163 patients (80% men; mean age, 49.5 years), of whom 87% were European American, 72% had left ventricular support, and 83% were bridge to transplant. The occurrence of renal failure, respiratory failure, bleeding events, and reoperations during the first 60 days after implantation significantly increased the risk of 1-year mortality. After controlling for gender, age, VAD type, and intention to treat, renal failure was the only major AE significantly associated with later mortality (hazard ratio, 2.96; p = .023).

CONCLUSIONS:

Specific AEs, including renal failure, respiratory and bleeding events, and reoperations, significantly decrease longer-term survival. Renal failure conferred a 3-fold increased risk of 1-year mortality. Peri-operative management should focus on strategies to mitigate risk for renal failure in order to maximize later outcomes.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Coração Auxiliar / Insuficiência Cardíaca Tipo de estudo: Etiology_studies / Incidence_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Limite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Revista: J Heart Lung Transplant Assunto da revista: CARDIOLOGIA / TRANSPLANTE Ano de publicação: 2010 Tipo de documento: Article País de afiliação: Estados Unidos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Coração Auxiliar / Insuficiência Cardíaca Tipo de estudo: Etiology_studies / Incidence_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Limite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Revista: J Heart Lung Transplant Assunto da revista: CARDIOLOGIA / TRANSPLANTE Ano de publicação: 2010 Tipo de documento: Article País de afiliação: Estados Unidos