Influence of locking bolt location on the mechanical properties of an interlocking nail in the canine femur.
Vet Surg
; 40(5): 522-30, 2011 Jul.
Article
em En
| MEDLINE
| ID: mdl-21615431
OBJECTIVE: To determine whether the fatigue properties of an interlocking nail (ILN) construct are influenced by metaphyseal or diaphyseal location of the locking bolt. STUDY DESIGN: Ex vivo mechanical investigation. SAMPLE POPULATION: Adult canine femora (n = 19 pairs). METHODS: Femora were implanted with a 6-mm diameter ILN. In 1 femur, the ILN was locked with a 2.7 mm bolt placed in the diaphysis; the ILN in the contralateral femur was locked with a bolt placed in the metaphysis. Constructs were tested to failure in axial loading (9 pairs) or torsion (10 pairs), with failure defined as displacement > 2 mm or a total of 500,000 cycles for axial loading, and rotation > 45° for torsional loading. Outcome measures included initial construct stiffness, number of cycles to failure, peak load, and peak torque. After testing, microradiography and histology were used to determine the location and nature of construct failure. RESULTS: Metaphyseal bolts failed at higher axial loads than diaphyseal bolts (P = .03), with bolt failure because of bending at the nail-bolt interface. All of the metaphyseal bolt constructs survived torsional testing whereas 9 of 10 diaphyseal bolt constructs failed catastrophically because of spiral fracture through the adjacent cortical bone. CONCLUSIONS: Placement of a locking bolt in metaphyseal bone extends fatigue life under axial loading and decreases the incidence of catastrophic failure under torsional loading.
Texto completo:
1
Coleções:
01-internacional
Base de dados:
MEDLINE
Assunto principal:
Pinos Ortopédicos
/
Cães
/
Fenômenos Mecânicos
/
Fraturas do Fêmur
/
Fêmur
/
Fixação Intramedular de Fraturas
Limite:
Animals
Idioma:
En
Revista:
Vet Surg
Ano de publicação:
2011
Tipo de documento:
Article
País de afiliação:
Estados Unidos