Your browser doesn't support javascript.
loading
Value of three-dimensional contrast-enhanced power Doppler ultrasound for characterizing adnexal masses.
Huchon, Cyrille; Metzger, Ulrike; Bats, Anne-Sophie; Bensaid, Cherazade; Chatellier, Gilles; Azizi, Michel; Lefrère-Belda, Marie-Aude; Dujardin, Arnaud; Bernard, Jean-Pierre; Lécuru, Fabrice.
Afiliação
  • Huchon C; Department of Gynecological and Oncological Surgery, European Hospital Georges Pompidou, AP-HP, Paris, France. cyrille.huchon@egp.aphp.fr
J Obstet Gynaecol Res ; 38(5): 832-40, 2012 May.
Article em En | MEDLINE | ID: mdl-22413992
ABSTRACT

AIMS:

The aim of this study was to assess the diagnostic performance of 3-D contrast-enhanced power Doppler ultrasonography (3-D CEPDUS) for differentiating benign and malignant adnexal masses. MATERIAL AND

METHODS:

Consecutive patients with adnexal masses were included prospectively and underwent 2-D ultrasonography and 3-D CEPDUS in a tertiary centre in Paris, France. The main outcome measure was the diagnostic accuracy of 3-D CEPDUS to diagnose malignant and borderline adnexal masses. The reference standard was the final histological examination. Two-dimensional ultrasonography and 3-D CEPDUS were compared using semiquantitative scores. Three-dimensional CEPDUS assessed vessel density, vessel pattern, and three vascular indexes in a 5-mL region of interest (vascularization index [VI], flow index [FI], and vascularization flow index [VFI]). The 2-D and 3-D examinations were done by different sonographers who were blinded to the other test. The pathologist was blinded to ultrasonography findings.

RESULTS:

Of 99 patients, 88 had benign tumors and were compared to the 11 patients with borderline (n = 5) or malignant (n = 6) tumors. The sensitivity of the subjective 2-D score was 55% (95% confidence interval [CI], 25-84) and specificity 94% (95%CI, 89-99). The sensitivity of the subjective 3-D score was 82% (95%CI, 58-100) and specificity 90% (95%CI, 83-96). Improvement of detection of malignant or borderline tumors by subjective 3-D score was 150%. Vessel density and patterns were not more efficient than the subjective 3-D score. The mean vascular index values were significantly different between benign and borderline/malignant groups VI, 7.2 versus 35.5 (P < 0.0001); FI, 37.0 versus 48.2 (P = 0.003); and VFI, 2.9 versus 17.6 (P < 0.0001), respectively.

CONCLUSIONS:

3-D CEPDUS improves detection of malignant and borderline adnexal masses.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Neoplasias Ovarianas / Ultrassonografia Doppler / Neovascularização Patológica Tipo de estudo: Diagnostic_studies Limite: Adult / Aged / Aged80 / Female / Humans / Middle aged Idioma: En Revista: J Obstet Gynaecol Res Assunto da revista: GINECOLOGIA / OBSTETRICIA Ano de publicação: 2012 Tipo de documento: Article País de afiliação: França

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Neoplasias Ovarianas / Ultrassonografia Doppler / Neovascularização Patológica Tipo de estudo: Diagnostic_studies Limite: Adult / Aged / Aged80 / Female / Humans / Middle aged Idioma: En Revista: J Obstet Gynaecol Res Assunto da revista: GINECOLOGIA / OBSTETRICIA Ano de publicação: 2012 Tipo de documento: Article País de afiliação: França