Your browser doesn't support javascript.
loading
Qualitative aspects and validation of a screening method for pesticides in vegetables and fruits based on liquid chromatography coupled to full scan high resolution (Orbitrap) mass spectrometry.
Mol, Hans G J; Zomer, Paul; de Koning, Maarten.
Afiliação
  • Mol HG; RIKILT Institute of Food Safety, Wageningen University and Research Centre, The Netherlands. hans.mol@wur.nl
Anal Bioanal Chem ; 403(10): 2891-908, 2012 Jul.
Article em En | MEDLINE | ID: mdl-22664752
ABSTRACT
The analytical capabilities of liquid chromatography with single-stage high-resolution mass spectrometry have been investigated with emphasis on qualitative aspects related to selective detection during screening and to identification. The study involved 21 different vegetable and fruit commodities, a screening database of 556 pesticides for evaluation of false positives, and a test set of 130 pesticides spiked to the commodities at 0.01, 0.05, and 0.20 mg/kg for evaluation of false negatives. The final method involved a QuEChERS-based sample preparation (without dSPE clean up) and full scan acquisition using alternating scan events without/with fragmentation, at a resolving power of 50,000. Analyte detection was based on extraction of the exact mass (±5 ppm) of the major adduct ion at the database retention time ±30 s and the presence of a second diagnostic ion. Various options for the additional ion were investigated and compared (other adduct ions, M + 1 or M + 2 isotopes, fragments). The two-ion approach for selective detection of the pesticides in the full scan data was compared with two alternative approaches based on response thresholds. Using the two-ion approach, the number of false positives out of 11,676 pesticide/commodity combinations targeted was 36 (0.3 %). The percentage of false negatives, assessed for 2,730 pesticide/commodity combinations, was 13 %, 3 %, and 1 % at the 0.01-, 0.05-, and 0.20-mg/kg level, respectively (slightly higher with fully automated detection). Following the SANCO/12495/2011 protocol for validation of screening methods, the screening detection limit was determined for 130 pesticides and found to be 0.01, 0.05, and ≥0.20 mg/kg for 86, 30, and 14 pesticides, respectively. For the detected pesticides in the spiked samples, the ability for unambiguous identification according to EU criteria was evaluated. A proposal for adaption of the criteria was made.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Praguicidas / Verduras / Análise de Alimentos / Frutas Tipo de estudo: Diagnostic_studies / Guideline / Prognostic_studies / Qualitative_research / Screening_studies Idioma: En Revista: Anal Bioanal Chem Ano de publicação: 2012 Tipo de documento: Article País de afiliação: Holanda

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Praguicidas / Verduras / Análise de Alimentos / Frutas Tipo de estudo: Diagnostic_studies / Guideline / Prognostic_studies / Qualitative_research / Screening_studies Idioma: En Revista: Anal Bioanal Chem Ano de publicação: 2012 Tipo de documento: Article País de afiliação: Holanda