Your browser doesn't support javascript.
loading
Nanocluster isotope distributions measured by electrospray time-of-flight mass spectrometry.
Comeau, Amanda N; Liu, JiangJiang; Khadka, Chhatra B; Corrigan, John F; Konermann, Lars.
Afiliação
  • Comeau AN; Department of Chemistry, The University of Western Ontario, London, Ontario, N6A 5B7, Canada.
Anal Chem ; 85(2): 1200-7, 2013 Jan 15.
Article em En | MEDLINE | ID: mdl-23214505
ABSTRACT
Electrospray ionization (ESI) mass spectrometry (MS) is a widely used tool for the characterization of organometallic nanoclusters. By matching experimental mass spectra with calculated isotope distributions it is possible to determine the elemental composition of these analytes. In this work we conduct ESI-MS investigations on M(14)E(13)Cl(2)(tmeda)(6) nanoclusters, where M is a transition metal, E represents a chalcogen, and tmeda is N,N,N',N'-tetramethyl-ethylenediamine. ESI mass spectra of these systems agree poorly with theoretical isotope distributions when data are acquired under standard conditions. This behavior is attributed to dead-time artifacts of the time-of-flight (TOF) analyzer used. It is well-known that excessively high TOF ion count rates lead to dead-time issues. Surprisingly, our data reveal that nanocluster spectra are affected by this problem even at moderate signal intensities that do not cause any problems for other types of analytes. This unexpected vulnerability is attributed to the extremely wide isotope distributions of the nanoclusters studied here. A good match between experimental and calculated nanocluster spectra is obtained only at ion count rates that are more than 1 order of magnitude below commonly used levels. Discrepancies between measured and theoretical isotope distributions have been observed in a number of previous ESI-MS nanocluster investigations. The dead-time issue identified here likely represents a contributing factor to the spectral distortions that were observed in those earlier studies. Using low-intensity ESI-MS conditions we demonstrate the feasibility of analyzing highly heterogeneous nanocluster samples that comprise subpopulations with a wide range of metal compositions.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Compostos Organometálicos / Nanoestruturas Tipo de estudo: Prognostic_studies Idioma: En Revista: Anal Chem Ano de publicação: 2013 Tipo de documento: Article País de afiliação: Canadá

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Compostos Organometálicos / Nanoestruturas Tipo de estudo: Prognostic_studies Idioma: En Revista: Anal Chem Ano de publicação: 2013 Tipo de documento: Article País de afiliação: Canadá