Randomized comparison of clinical outcomes between intravascular ultrasound and angiography-guided drug-eluting stent implantation for long coronary artery stenoses.
Kim, Jung-Sun; Kang, Tae-Soo; Mintz, Gary S; Park, Byoung-Eun; Shin, Dong-Ho; Kim, Byeong-Keuk; Ko, Young-Guk; Choi, Donghoon; Jang, Yangsoo; Hong, Myeong-Ki.
Afiliação
  • Kim JS; Division of Cardiology, Severance Cardiovascular Hospital, Yonsei University College of Medicine, Seoul, Korea.
JACC Cardiovasc Interv ; 6(4): 369-76, 2013 Apr.
Article em En | MEDLINE | ID: mdl-23523455
ABSTRACT

OBJECTIVES:

This study sought to assess the impact of intravascular ultrasound (IVUS) guidance on clinical outcomes following drug-eluting stent implantation when treating long lesions.

BACKGROUND:

The role of IVUS guidance when treating long lesions has been tested during bare-metal stent, but not during drug-eluting stent, implantation.

METHODS:

A total of 543 patients treated with stents ≥ 28 mm in length were randomly assigned to IVUS guidance (n = 269) versus angiography guidance (n = 274). The primary endpoint was a composite of major adverse cardiac events (MACE), including cardiovascular death, myocardial infarction, target vessel revascularization, or stent thrombosis at 1 year following intervention.

RESULTS:

In the intention-to-treat analysis, total stent length was 32.4 mm in the IVUS-guided arm versus 32.3 mm in angiography-guided arm (p = 0.84). Adjunct post-dilation was more frequently performed in the IVUS-guided arm (54.6% vs. 44.5%, p = 0.03); post-intervention minimal lumen diameters were similar (2.55 vs. 2.55 mm, respectively, p = 0.50); and MACE occurred in 12 (4.5%) patients in IVUS-guided arm and in 20 (7.3%) patients in the angiography-guided arm (p = 0.16). However, among the 269 patients assigned to IVUS guidance, IVUS was not used in 13 patients (4.8%); conversely, in 274 patients assigned to angiography alone, 41 patients (15.0%) were treated with IVUS guidance. Therefore, in a per-protocol analysis according to actual IVUS usage, minimum lumen diameter was larger (2.58 vs. 2.51 mm, p = 0.04), and MACE rates were lower 4.0% in the IVUS-guided arm versus 8.1% in the angiography-guided arm (p = 0.048).

CONCLUSIONS:

A strategy of routine IVUS for drug-eluting stent implantation in long lesions did not improve the 1-year MACE rates. The IVUS use per operator decision was associated with improved results. (A New Strategy Regarding Discontinuation of Dual Antiplatelet; NCT01145079).
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Angiografia Coronária / Ultrassonografia de Intervenção / Estenose Coronária / Stents Farmacológicos / Intervenção Coronária Percutânea Tipo de estudo: Clinical_trials / Etiology_studies / Guideline / Observational_studies / Prognostic_studies / Risk_factors_studies Limite: Aged / Female / Humans / Male / Middle aged País/Região como assunto: Asia Idioma: En Revista: JACC Cardiovasc Interv Assunto da revista: ANGIOLOGIA / CARDIOLOGIA Ano de publicação: 2013 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Angiografia Coronária / Ultrassonografia de Intervenção / Estenose Coronária / Stents Farmacológicos / Intervenção Coronária Percutânea Tipo de estudo: Clinical_trials / Etiology_studies / Guideline / Observational_studies / Prognostic_studies / Risk_factors_studies Limite: Aged / Female / Humans / Male / Middle aged País/Região como assunto: Asia Idioma: En Revista: JACC Cardiovasc Interv Assunto da revista: ANGIOLOGIA / CARDIOLOGIA Ano de publicação: 2013 Tipo de documento: Article