Your browser doesn't support javascript.
loading
Multicenter evaluation of the Vitek MS matrix-assisted laser desorption ionization-time of flight mass spectrometry system for identification of Gram-positive aerobic bacteria.
Rychert, Jenna; Burnham, Carey-Ann D; Bythrow, Maureen; Garner, Omai B; Ginocchio, Christine C; Jennemann, Rebecca; Lewinski, Michael A; Manji, Ryhana; Mochon, A Brian; Procop, Gary W; Richter, Sandra S; Sercia, Linda; Westblade, Lars F; Ferraro, Mary Jane; Branda, John A.
Afiliação
  • Rychert J; Department of Pathology, Massachusetts General Hospital and Harvard Medical School, Boston, Massachusetts, USA. jrychert@partners.org
J Clin Microbiol ; 51(7): 2225-31, 2013 Jul.
Article em En | MEDLINE | ID: mdl-23658261
ABSTRACT
Matrix-assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF) is gaining momentum as a tool for bacterial identification in the clinical microbiology laboratory. Compared with conventional methods, this technology can more readily and conveniently identify a wide range of organisms. Here, we report the findings from a multicenter study to evaluate the Vitek MS v2.0 system (bioMérieux, Inc.) for the identification of aerobic Gram-positive bacteria. A total of 1,146 unique isolates, representing 13 genera and 42 species, were analyzed, and results were compared to those obtained by nucleic acid sequence-based identification as the reference method. For 1,063 of 1,146 isolates (92.8%), the Vitek MS provided a single identification that was accurate to the species level. For an additional 31 isolates (2.7%), multiple possible identifications were provided, all correct at the genus level. Mixed-genus or single-choice incorrect identifications were provided for 18 isolates (1.6%). Although no identification was obtained for 33 isolates (2.9%), there was no specific bacterial species for which the Vitek MS consistently failed to provide identification. In a subset of 463 isolates representing commonly encountered important pathogens, 95% were accurately identified to the species level and there were no misidentifications. Also, in all but one instance, the Vitek MS correctly differentiated Streptococcus pneumoniae from other viridans group streptococci. The findings demonstrate that the Vitek MS system is highly accurate for the identification of Gram-positive aerobic bacteria in the clinical laboratory setting.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Bactérias Aeróbias / Técnicas Bacteriológicas / Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz / Bactérias Gram-Positivas Tipo de estudo: Clinical_trials / Diagnostic_studies / Evaluation_studies / Prognostic_studies Limite: Humans Idioma: En Revista: J Clin Microbiol Ano de publicação: 2013 Tipo de documento: Article País de afiliação: Estados Unidos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Bactérias Aeróbias / Técnicas Bacteriológicas / Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz / Bactérias Gram-Positivas Tipo de estudo: Clinical_trials / Diagnostic_studies / Evaluation_studies / Prognostic_studies Limite: Humans Idioma: En Revista: J Clin Microbiol Ano de publicação: 2013 Tipo de documento: Article País de afiliação: Estados Unidos