A comparison of the accuracy of three removable die systems and two die materials.
Eur J Prosthodont Restor Dent
; 21(3): 115-9, 2013 Sep.
Article
em En
| MEDLINE
| ID: mdl-24261103
The purpose of this study was to evaluate the dimensional shift of three commonly used die systems (Conventional system, Pindex system, Di-Lok tray system) with two commercially available type IV die stones (Ultra rock and Pearl stone). Under controlled conditions, ten casts, each with two removable dies, were constructed for each system for a total of 30 casts and 60 removable dies. Before and after sectioning measurements to within 0.01 mm in horizontal and vertical planes were recorded and differences calculated. Data were analyzed with 't' tests, one way analysis of variance and post hoc Tukey test. The results demonstrated that among the die systems compared, no single system was superior to the others in all respects. But among the die materials, dies poured in Pearl stone exhibited more dimensional changes than Ultra rock (p<0.05). Selection of die material is as critical as selection of any particular die system for successful fabrication of fixed partial denture and implant prosthesis.
Buscar no Google
Coleções:
01-internacional
Base de dados:
MEDLINE
Assunto principal:
Técnica de Fundição Odontológica
/
Planejamento de Dentadura
/
Planejamento de Prótese Dentária
/
Modelos Dentários
Tipo de estudo:
Evaluation_studies
Idioma:
En
Revista:
Eur J Prosthodont Restor Dent
Assunto da revista:
ODONTOLOGIA
Ano de publicação:
2013
Tipo de documento:
Article
País de afiliação:
Índia