Comparison of myelin water fraction from multiecho T2 decay curve and steady-state methods.
Zhang, Jing; Kolind, Shannon H; Laule, Cornelia; MacKay, Alex L.
Afiliação
  • Zhang J; UBC MRI Research Centre, Department of Radiology, University of British Columbia, Vancouver, BC, Canada.
  • Kolind SH; Division of Neurology, Department of Medicine, University of British Columbia, Vancouver, BC, Canada.
  • Laule C; UBC MRI Research Centre, Department of Radiology, University of British Columbia, Vancouver, BC, Canada.
  • MacKay AL; Department of Pathology & Laboratory Medicine, University of British Columbia, Vancouver, BC, Canada.
Magn Reson Med ; 73(1): 223-32, 2015 Jan.
Article em En | MEDLINE | ID: mdl-24515972
ABSTRACT

PURPOSE:

Myelin water fraction is conventionally measured from the T2 decay curve. Recently, a steady-state approach entitled multicomponent-driven equilibrium single pulse observation of T1 /T2 (mcDESPOT) was employed for myelin water fraction mapping. However, no direct comparison between the established multiecho T2 relaxation method and mcDESPOT has been performed.

METHODS:

Gradient and spin echo (GRASE) acquired T2 decay curve and mcDESPOT measurements were acquired from 10 healthy volunteers using a 3T MRI. We compared myelin water fraction, transmit radio frequency field (B1 ), and T2 's of intra- and extracellular water obtained from both methods.

RESULTS:

For all brain regions examined, myelin water fractions from mcDESPOT were significantly higher than those from multiecho GRASE. B1 maps were qualitatively similar between GRASE and mcDESPOT, but multicomponent T2 times were significantly different. To investigate the effect of exchange, mcDESPOT data were analyzed with and without exchange. When exchange was turned off, intra- and extracellular T2 times from mcDESPOT were roughly consistent with GRASE results; however, myelin water fractions derived from mcDESPOT were still significantly higher than those derived from GRASE.

CONCLUSION:

Myelin water fraction values derived from mcDESPOT cannot be considered to be equivalent to those derived from T2 decay curve approaches.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Água Corporal / Química Encefálica / Interpretação de Imagem Assistida por Computador / Imagem Ecoplanar / Bainha de Mielina / Fibras Nervosas Mielinizadas Tipo de estudo: Diagnostic_studies / Evaluation_studies Limite: Adult / Female / Humans / Male / Middle aged Idioma: En Revista: Magn Reson Med Assunto da revista: DIAGNOSTICO POR IMAGEM Ano de publicação: 2015 Tipo de documento: Article País de afiliação: Canadá

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Água Corporal / Química Encefálica / Interpretação de Imagem Assistida por Computador / Imagem Ecoplanar / Bainha de Mielina / Fibras Nervosas Mielinizadas Tipo de estudo: Diagnostic_studies / Evaluation_studies Limite: Adult / Female / Humans / Male / Middle aged Idioma: En Revista: Magn Reson Med Assunto da revista: DIAGNOSTICO POR IMAGEM Ano de publicação: 2015 Tipo de documento: Article País de afiliação: Canadá