Your browser doesn't support javascript.
loading
Volumetric measurement of polyacrylamide hydrogel injected for breast augmentation using magnetic resonance imaging.
Hu, Jiejie; Liu, Chunjun; Chen, Lin; Xing, Wenshan; Luan, Jie.
Afiliação
  • Hu J; Department of Aesthetic and Plastic Breast Surgery, Plastic Surgery Hospital, Peking Union Medical College, Chinese Academy of Medical Sciences, Beijing 100144, P.R. China.
  • Liu C; Department of Aesthetic and Plastic Breast Surgery, Plastic Surgery Hospital, Peking Union Medical College, Chinese Academy of Medical Sciences, Beijing 100144, P.R. China.
  • Chen L; Department of Aesthetic and Plastic Breast Surgery, Plastic Surgery Hospital, Peking Union Medical College, Chinese Academy of Medical Sciences, Beijing 100144, P.R. China.
  • Xing W; Department of Aesthetic and Plastic Breast Surgery, Plastic Surgery Hospital, Peking Union Medical College, Chinese Academy of Medical Sciences, Beijing 100144, P.R. China.
  • Luan J; Department of Aesthetic and Plastic Breast Surgery, Plastic Surgery Hospital, Peking Union Medical College, Chinese Academy of Medical Sciences, Beijing 100144, P.R. China.
Exp Ther Med ; 7(3): 681-684, 2014 Mar.
Article em En | MEDLINE | ID: mdl-24520267
Volumetric measurement of polyacrylamide hydrogel (PAHG) is useful for surgical planning. It is not only a significant factor in the preoperative evaluation of breast augmentation, but may also directly affect the postoperative shape of the breast. The objective of the present study was to evaluate whether magnetic resonance imaging (MRI) is able to provide precise calculations of injected PAHG volumes. MRI scans of ten randomly selected patients were imported to Mimics software. The volumes of PAHG were obtained following the reconstruction of the injected PAHG. In order to assess the precision and observer independency of the technique, the volumes of PAHG were estimated by three plastic surgeons using this method. No significant differences were identified among the PAHG injection volumes calculated by the three observers (P=0.173). The intra-observer correlation coefficient was 0.964, which indicates the precision and feasibility of this method for calculating the volume of PAHG. The use of MRI in combination with Mimics software to calculate PAHG volumes is likely to be of significant clinical benefit in preoperative surgical planning.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Prognostic_studies Idioma: En Revista: Exp Ther Med Ano de publicação: 2014 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Prognostic_studies Idioma: En Revista: Exp Ther Med Ano de publicação: 2014 Tipo de documento: Article