Your browser doesn't support javascript.
loading
Linac4 low energy beam measurements with negative hydrogen ions.
Scrivens, R; Bellodi, G; Crettiez, O; Dimov, V; Gerard, D; Granemann Souza, E; Guida, R; Hansen, J; Lallement, J-B; Lettry, J; Lombardi, A; Midttun, Ø; Pasquino, C; Raich, U; Riffaud, B; Roncarolo, F; Valerio-Lizarraga, C A; Wallner, J; Yarmohammadi Satri, M; Zickler, T.
Afiliação
  • Scrivens R; CERN, 1211 Geneva 23, Switzerland.
  • Bellodi G; CERN, 1211 Geneva 23, Switzerland.
  • Crettiez O; CERN, 1211 Geneva 23, Switzerland.
  • Dimov V; CERN, 1211 Geneva 23, Switzerland.
  • Gerard D; CERN, 1211 Geneva 23, Switzerland.
  • Granemann Souza E; CERN, 1211 Geneva 23, Switzerland.
  • Guida R; CERN, 1211 Geneva 23, Switzerland.
  • Hansen J; CERN, 1211 Geneva 23, Switzerland.
  • Lallement JB; CERN, 1211 Geneva 23, Switzerland.
  • Lettry J; CERN, 1211 Geneva 23, Switzerland.
  • Lombardi A; CERN, 1211 Geneva 23, Switzerland.
  • Midttun Ø; CERN, 1211 Geneva 23, Switzerland.
  • Pasquino C; CERN, 1211 Geneva 23, Switzerland.
  • Raich U; CERN, 1211 Geneva 23, Switzerland.
  • Riffaud B; CERN, 1211 Geneva 23, Switzerland.
  • Roncarolo F; CERN, 1211 Geneva 23, Switzerland.
  • Valerio-Lizarraga CA; CERN, 1211 Geneva 23, Switzerland.
  • Wallner J; CERN, 1211 Geneva 23, Switzerland.
  • Yarmohammadi Satri M; CERN, 1211 Geneva 23, Switzerland.
  • Zickler T; CERN, 1211 Geneva 23, Switzerland.
Rev Sci Instrum ; 85(2): 02A729, 2014 Feb.
Article em En | MEDLINE | ID: mdl-24593463
ABSTRACT
Linac4, a 160 MeV normal-conducting H(-) linear accelerator, is the first step in the upgrade of the beam intensity available from the LHC proton injectors at CERN. The Linac4 Low Energy Beam Transport (LEBT) line from the pulsed 2 MHz RF driven ion source, to the 352 MHz RFQ (Radiofrequency Quadrupole) has been built and installed at a test stand, and has been used to transport and match to the RFQ a pulsed 14 mA H(-) beam at 45 keV. A temporary slit-and-grid emittance measurement system has been put in place to characterize the beam delivered to the RFQ. In this paper a description of the LEBT and its beam diagnostics is given, and the results of beam emittance measurements and beam transmission measurements through the RFQ are compared with the expectation from simulations.

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Rev Sci Instrum Ano de publicação: 2014 Tipo de documento: Article País de afiliação: Suíça

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Rev Sci Instrum Ano de publicação: 2014 Tipo de documento: Article País de afiliação: Suíça