Your browser doesn't support javascript.
loading
Dose-reduced CT with model-based iterative reconstruction in evaluations of hepatic steatosis: how low can we go?
Yasaka, Koichiro; Katsura, Masaki; Akahane, Masaaki; Sato, Jiro; Matsuda, Izuru; Ohtomo, Kuni.
Afiliação
  • Yasaka K; Department of Radiology, Graduate School of Medicine, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo 113-8655, Japan. Electronic address: koyasaka@gmail.com.
  • Katsura M; Department of Radiology, Graduate School of Medicine, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo 113-8655, Japan.
  • Akahane M; NTT Medical Center Tokyo, 5-9-22 Higashi-Gotanda, Shinagawa-ku, Tokyo 141-8625, Japan.
  • Sato J; Department of Radiology, Graduate School of Medicine, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo 113-8655, Japan.
  • Matsuda I; Kanto Rosai Hospital, 1-1 Kizukisumiyoshi-cho, Nakahara-ku, Kawasaki, Kanagawa 211-8510, Japan.
  • Ohtomo K; Department of Radiology, Graduate School of Medicine, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo 113-8655, Japan.
Eur J Radiol ; 83(7): 1063-1068, 2014 Jul.
Article em En | MEDLINE | ID: mdl-24775685
PURPOSE: To determine whether dose-reduced CT with model-based iterative image reconstruction (MBIR) is a useful tool with which to diagnose hepatic steatosis. MATERIALS AND METHODS: This prospective clinical study approved by our Institutional Review Board included 103 (67 men and 36 women; mean age, 64.3 years) patients who provided written informed consent to undergo unenhanced CT. Images of reference-dose CT (RDCT) with filtered back projection (R-FBP) and low- and ultralow-dose CT (dose-length product; 24 and 9% of that of RDCT) with MBIR (L-MBIR and UL-MBIR) were reconstructed. Mean CT numbers of liver (CT[L]) and spleen (CT[S]), and quotient (CT[L/S]) of CT[L] and CT[S] were calculated from selected regions of interest. Bias and limits of agreement (LOA) of CT[L] and CT[L/S] in L-MBIR and UL-MBIR (vs. R-FBP) were assessed using Bland-Altman analyses. Diagnostic methods for hepatic steatosis of CT[L]<48 Hounsfield units (HU) and CT[L/S]<1.1 were applied to L-MBIR and UL-MBIR using R-FBP as the reference standard. RESULTS: Bias was larger for CT[L] in UL-MBIR than in L-MBIR (-3.18HU vs. -1.73HU). The LOA of CT[L/S] was larger for UL-MBIR than for L-MBIR (±0.425 vs. ±0.245) and outliers were identified in CT[L/S] of UL-MBIR. Accuracy (0.92-0.95) and the area under the receiver operating characteristics curve (0.976-0.992) were high for each method, but some were slightly lower in UL-MBIR than L-MBIR. CONCLUSION: Dose-reduced CT reconstructed with MBIR is applicable to diagnose hepatic steatosis, however, a low dose of radiation might be preferable.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Proteção Radiológica / Algoritmos / Interpretação de Imagem Radiográfica Assistida por Computador / Tomografia Computadorizada por Raios X / Fígado Gorduroso / Modelos Biológicos Tipo de estudo: Diagnostic_studies / Observational_studies / Prognostic_studies Limite: Female / Humans / Male / Middle aged Idioma: En Revista: Eur J Radiol Ano de publicação: 2014 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Proteção Radiológica / Algoritmos / Interpretação de Imagem Radiográfica Assistida por Computador / Tomografia Computadorizada por Raios X / Fígado Gorduroso / Modelos Biológicos Tipo de estudo: Diagnostic_studies / Observational_studies / Prognostic_studies Limite: Female / Humans / Male / Middle aged Idioma: En Revista: Eur J Radiol Ano de publicação: 2014 Tipo de documento: Article