Pseudo-malfunction of the Coloplast Titan Inflatable Penile Prosthesis One-Touch Release Pump.
Garber, Bruce B; Khurgin, Jacob L; Stember, Doron S; Perito, Paul E.
Afiliação
  • Garber BB; Department of Urology, Hahnemann University Hospital, Drexel University College of Medicine, Philadelphia, PA.
  • Khurgin JL; Department of Urology, Einstein Medical Center, Philadelphia, PA. Electronic address: jacobkhurgin@gmail.com.
  • Stember DS; Department of Urology, Mount Sinai Beth Israel, New York, NY.
  • Perito PE; Department of Urology, Coral Gables Hospital, Coral Gables, FL.
Urology ; 84(4): 857-9, 2014 Oct.
Article em En | MEDLINE | ID: mdl-25260446
OBJECTIVE: To define and describe a type of pseudo-malfunction of the Coloplast Titan Inflatable Penile Prosthesis (IPP) One-Touch Release (OTR) pump (Coloplast Corp, Minneapolis, MN). MATERIALS AND METHODS: We retrospectively reviewed a consecutive series of 550 patients with refractory organic erectile dysfunction who were implanted with a Coloplast Titan IPP with the OTR pump during a period of approximately 4 years. RESULTS: All patients were implanted using standard techniques through an infrapubic or penoscrotal approach. Twenty-nine patients (5.3%) complained that their IPP would not inflate and that the pump bulb felt "hard." Examination revealed that their IPP was working normally; however, the inflate/deflate valve disc had become stuck in the deflate position. Very firm pressure had to be applied to the pump bulb to move the valve disc into the inflate position. Once this was accomplished, the device inflated and deflated normally. Another 14 patients (2.5%) reported this phenomenon to us but were able to apply enough pressure on the pump bulb to rectify it. CONCLUSION: The inflate/deflate valve disc in the Coloplast Titan OTR pump can occasionally become stuck in the deflate position (7.8% of patients in our experience). Patients may be unable to inflate the device and return for evaluation. In all cases we have encountered, firm pressure on the pump bulb caused the valve to shift into the inflate position, and the device worked properly thereafter. Patients and implanting urologists should be aware of this issue and of the way in which it can be rectified.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Falha de Prótese / Prótese de Pênis / Disfunção Erétil Tipo de estudo: Observational_studies Limite: Humans / Male Idioma: En Revista: Urology Ano de publicação: 2014 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Falha de Prótese / Prótese de Pênis / Disfunção Erétil Tipo de estudo: Observational_studies Limite: Humans / Male Idioma: En Revista: Urology Ano de publicação: 2014 Tipo de documento: Article