Your browser doesn't support javascript.
loading
Durability of Pulmonary Vein Isolation with Cryoballoon Ablation: Results from the Sustained PV Isolation with Arctic Front Advance (SUPIR) Study.
Reddy, Vivek Y; Sediva, Lucie; Petru, Jan; Skoda, Jan; Chovanec, Milan; Chitovova, Zita; Di Stefano, Paola; Rubin, Ethel; Dukkipati, Srinivas; Neuzil, Petr.
Afiliação
  • Reddy VY; Cardiac Arrhythmia Service of the Mt. Sinai Hospital, New York, New York, USA.
  • Sediva L; Homolka Hospital, Prague, Czech Republic.
  • Petru J; Homolka Hospital, Prague, Czech Republic.
  • Skoda J; Homolka Hospital, Prague, Czech Republic.
  • Chovanec M; Homolka Hospital, Prague, Czech Republic.
  • Chitovova Z; Homolka Hospital, Prague, Czech Republic.
  • Di Stefano P; EMEA Regional Clinical Center, Medtronic Clinical Research Institute, Milan, Italy.
  • Rubin E; Medtronic Inc., Minneapolis, Minnesota, USA.
  • Dukkipati S; Cardiac Arrhythmia Service of the Mt. Sinai Hospital, New York, New York, USA.
  • Neuzil P; Homolka Hospital, Prague, Czech Republic.
J Cardiovasc Electrophysiol ; 26(5): 493-500, 2015 May.
Article em En | MEDLINE | ID: mdl-25644659
ABSTRACT

INTRODUCTION:

Pulmonary vein (PV) reconnection remains the most important cause of AF recurrence after AF ablation. The second-generation cryoballoon catheter's ability to achieve durable PV isolation was assessed in a prospective nonrandomized clinical trial. METHODS AND

RESULTS:

PV isolation was performed by 4-minute ablations. Following verification of electrical isolation by a multielectrode mapping catheter, 1 additional lesion per PV was applied. Esophageal temperatures were monitored and all patients underwent postprocedure esophageal endoscopy. All patients underwent a second PV remapping procedure at ∼3 months to assess for PVI durability. Eighty-four (100%) veins were acutely isolated using only the 28 mm cryoballoon in 21 consecutive PAF patients with 2.2 ± 0.6 cryoapplications per vein, with the majority (83%) occurring after a single freeze. One patient presented with hematemesis and an esophageal ulceration that was treated conservatively; there were no episodes of esophageal fistula or phrenic nerve palsy. At 3.4 (2.9-4.1) months postablation, 68/75 veins (91%) remained electrically isolated; all PVs remained durably isolated in 79% of patients. Two patients accounted for 5 of 7 reconducting veins. The most common site for reconnection was the inferior aspect of the RIPV (3/7 reconnections). Reconnected veins had poorer occlusion at the index ablation procedure than veins that maintained chronic isolation (occlusion grade 2.9 ± 0.7 vs. 3.4 ± 0.7, P = 0.001). Clinical AF recurrence was detected in 2 patients (11%) at follow-up.

CONCLUSIONS:

The improved thermodynamic characteristics of the second-generation cryoballoon led to a high rate of both single-shot PVI and chronic lesion durability. This high rate of durable PV isolation is anticipated to translate to improved clinical outcome.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Veias Pulmonares / Fibrilação Atrial / Criocirurgia / Cateteres Cardíacos Tipo de estudo: Clinical_trials / Diagnostic_studies / Observational_studies Limite: Aged / Female / Humans / Male / Middle aged País/Região como assunto: Europa Idioma: En Revista: J Cardiovasc Electrophysiol Assunto da revista: ANGIOLOGIA / CARDIOLOGIA / FISIOLOGIA Ano de publicação: 2015 Tipo de documento: Article País de afiliação: Estados Unidos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Veias Pulmonares / Fibrilação Atrial / Criocirurgia / Cateteres Cardíacos Tipo de estudo: Clinical_trials / Diagnostic_studies / Observational_studies Limite: Aged / Female / Humans / Male / Middle aged País/Região como assunto: Europa Idioma: En Revista: J Cardiovasc Electrophysiol Assunto da revista: ANGIOLOGIA / CARDIOLOGIA / FISIOLOGIA Ano de publicação: 2015 Tipo de documento: Article País de afiliação: Estados Unidos