ABSTRACT
INTRODUCTION:
Pulmonary vein (PV) reconnection remains the most important cause of AF recurrence after AF ablation. The second-generation cryoballoon catheter's ability to achieve durable PV isolation was assessed in a prospective nonrandomized clinical trial. METHODS ANDRESULTS:
PV isolation was performed by 4-minute ablations. Following verification of electrical isolation by a multielectrode mapping catheter, 1 additional lesion per PV was applied. Esophageal temperatures were monitored and all patients underwent postprocedure esophageal endoscopy. All patients underwent a second PV remapping procedure at â¼3 months to assess for PVI durability. Eighty-four (100%) veins were acutely isolated using only the 28 mm cryoballoon in 21 consecutive PAF patients with 2.2 ± 0.6 cryoapplications per vein, with the majority (83%) occurring after a single freeze. One patient presented with hematemesis and an esophageal ulceration that was treated conservatively; there were no episodes of esophageal fistula or phrenic nerve palsy. At 3.4 (2.9-4.1) months postablation, 68/75 veins (91%) remained electrically isolated; all PVs remained durably isolated in 79% of patients. Two patients accounted for 5 of 7 reconducting veins. The most common site for reconnection was the inferior aspect of the RIPV (3/7 reconnections). Reconnected veins had poorer occlusion at the index ablation procedure than veins that maintained chronic isolation (occlusion grade 2.9 ± 0.7 vs. 3.4 ± 0.7, P = 0.001). Clinical AF recurrence was detected in 2 patients (11%) at follow-up.CONCLUSIONS:
The improved thermodynamic characteristics of the second-generation cryoballoon led to a high rate of both single-shot PVI and chronic lesion durability. This high rate of durable PV isolation is anticipated to translate to improved clinical outcome.Palavras-chave
Texto completo:
1
Coleções:
01-internacional
Base de dados:
MEDLINE
Assunto principal:
Veias Pulmonares
/
Fibrilação Atrial
/
Criocirurgia
/
Cateteres Cardíacos
Tipo de estudo:
Clinical_trials
/
Diagnostic_studies
/
Observational_studies
Limite:
Aged
/
Female
/
Humans
/
Male
/
Middle aged
País/Região como assunto:
Europa
Idioma:
En
Revista:
J Cardiovasc Electrophysiol
Assunto da revista:
ANGIOLOGIA
/
CARDIOLOGIA
/
FISIOLOGIA
Ano de publicação:
2015
Tipo de documento:
Article
País de afiliação:
Estados Unidos