Your browser doesn't support javascript.
loading
Centerband-only analysis of rotor-unsynchronized spin echo for measurement of lipid (31) P chemical shift anisotropy.
Umegawa, Yuichi; Yamaguchi, Toshiyuki; Murata, Michio; Matsuoka, Shigeru.
Afiliação
  • Umegawa Y; JST ERATO, Lipid Active Structure Project, Osaka University, 1-1 Machikaneyama, Toyonaka, Osaka Prefecture, 560-0043, Japan.
  • Yamaguchi T; Department of Chemistry, Graduate School of Science, Osaka University, 1-1 Machikaneyama, Toyonaka, Osaka Prefecture, 560-0043, Japan.
  • Murata M; Project Research Centre for Fundamental Science, Osaka University, 1-1 Machikaneyama, Toyonaka, Osaka Prefecture, 560-0043, Japan.
  • Matsuoka S; JST ERATO, Lipid Active Structure Project, Osaka University, 1-1 Machikaneyama, Toyonaka, Osaka Prefecture, 560-0043, Japan.
Magn Reson Chem ; 53(7): 514-9, 2015 Jul.
Article em En | MEDLINE | ID: mdl-26017552
ABSTRACT
Structural diversity and molecular flexibility of phospholipids are essential for biological membranes to play key roles in numerous cellular processes. Uncovering the behavior of individual lipids in membrane dynamics is crucial for understanding the molecular mechanisms underlying biological functions of cell membranes. In this paper, we introduce a simple method to investigate dynamics of lipid molecules in multi-component systems by measuring the (31) P chemical shift anisotropy (CSA) under magic angle spinning (MAS) conditions. For achieving both signal separation and CSA determination, we utilized a centerband-only analysis of rotor-unsynchronized spin echo (COARSE). This analysis is based on the curve fitting of periodic modulation of centerband intensity along the interpulse delay time in rotor-unsynchronized spin-echo experiments. The utility of COARSE was examined by using phospholipid vesicles, a three-component lipid raft model system, and archaeal purple membranes. We found that the apparent advantages of this method are high resolution and high sensitivity given by the moderate MAS speed and the one-dimensional acquisition with short spin-echo delays. COARSE provides an alternative method for CSA measurement that is effective in the investigation of lipid polymorphologies.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Fosfolipídeos / Fósforo Tipo de estudo: Prognostic_studies Idioma: En Revista: Magn Reson Chem Assunto da revista: QUIMICA Ano de publicação: 2015 Tipo de documento: Article País de afiliação: Japão

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Fosfolipídeos / Fósforo Tipo de estudo: Prognostic_studies Idioma: En Revista: Magn Reson Chem Assunto da revista: QUIMICA Ano de publicação: 2015 Tipo de documento: Article País de afiliação: Japão