Your browser doesn't support javascript.
loading
T1 at 1.5T and 3T compared with conventional T2* at 1.5T for cardiac siderosis.
Alam, Mohammed H; Auger, Dominique; Smith, Gillian C; He, Taigang; Vassiliou, Vassilis; Baksi, A John; Wage, Rick; Drivas, Peter; Feng, Yanqiu; Firmin, David N; Pennell, Dudley J.
Afiliação
  • Alam MH; NIHR Cardiovascular Biomedical Research Unit, Royal Brompton Hospital, Sydney Street, London, SW3 6NP, UK. M.Alam@rbht.nhs.uk.
  • Auger D; Imperial College London, London, UK. M.Alam@rbht.nhs.uk.
  • Smith GC; NIHR Cardiovascular Biomedical Research Unit, Royal Brompton Hospital, Sydney Street, London, SW3 6NP, UK. D.Auger@rbht.nhs.uk.
  • He T; Imperial College London, London, UK. D.Auger@rbht.nhs.uk.
  • Vassiliou V; NIHR Cardiovascular Biomedical Research Unit, Royal Brompton Hospital, Sydney Street, London, SW3 6NP, UK. G.Smith@rbht.nhs.uk.
  • Baksi AJ; Imperial College London, London, UK. G.Smith@rbht.nhs.uk.
  • Wage R; St George's, University of London, London, UK. tgheuk@gmail.com.
  • Drivas P; NIHR Cardiovascular Biomedical Research Unit, Royal Brompton Hospital, Sydney Street, London, SW3 6NP, UK. V.Vassiliou@rbht.nhs.uk.
  • Feng Y; Imperial College London, London, UK. V.Vassiliou@rbht.nhs.uk.
  • Firmin DN; NIHR Cardiovascular Biomedical Research Unit, Royal Brompton Hospital, Sydney Street, London, SW3 6NP, UK. J.Baksi@rbht.nhs.uk.
  • Pennell DJ; Imperial College London, London, UK. J.Baksi@rbht.nhs.uk.
J Cardiovasc Magn Reson ; 17: 102, 2015 Nov 24.
Article em En | MEDLINE | ID: mdl-26602203
ABSTRACT

BACKGROUND:

Myocardial black blood (BB) T2* relaxometry at 1.5T provides robust, reproducible and calibrated non-invasive assessment of cardiac iron burden. In vitro data has shown that like T2*, novel native Modified Look-Locker Inversion recovery (MOLLI) T1 shortens with increasing tissue iron. The relative merits of T1 and T2* are largely unexplored. We compared the established 1.5T BB T2* technique against native T1 values at 1.5T and 3T in iron overload patients and in normal volunteers.

METHODS:

A total of 73 subjects (42 male) were recruited, comprising 20 healthy volunteers (controls) and 53 patients (thalassemia major 22, sickle cell disease 9, hereditary hemochromatosis 9, other iron overload conditions 13). Single mid-ventricular short axis slices were acquired for BB T2* at 1.5T and MOLLI T1 quantification at 1.5T and 3T.

RESULTS:

In healthy volunteers, median T1 was 1014 ms (full range 939-1059 ms) at 1.5T and modestly increased to 1165ms (full range 1056-1224 ms) at 3T. All patients with significant cardiac iron overload (1.5T T2* values <20 ms) had T1 values <939 ms at 1.5T, and <1056 ms at 3T. Associations between T2* and T1 were found to be moderate with y =377 · x(0.282) at 1.5T (R(2) = 0.717), and y =406 · x(0.294) at 3T (R(2) = 0.715). Measures of reproducibility of T1 appeared superior to T2*.

CONCLUSIONS:

T1 mapping at 1.5T and at 3T can identify individuals with significant iron loading as defined by the current gold standard T2* at 1.5T. However, there is significant scatter between results which may reflect measurement error, but it is also possible that T1 interacts with T2*, or is differentially sensitive to aspects of iron chemistry or other biology. Hurdles to clinical implementation of T1 include the lack of calibration against human myocardial iron concentration, no demonstrated relation to cardiac outcomes, and variation in absolute T1 values between scanners, which makes inter-centre comparisons difficult. The relative merits of T1 at 3T versus T2* at 3T require further consideration.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Processamento de Imagem Assistida por Computador / Imageamento por Ressonância Magnética / Siderose / Ferro / Cardiomiopatias / Miocárdio Tipo de estudo: Observational_studies / Prognostic_studies / Risk_factors_studies Limite: Adult / Female / Humans / Male / Middle aged Idioma: En Revista: J Cardiovasc Magn Reson Assunto da revista: ANGIOLOGIA / CARDIOLOGIA / DIAGNOSTICO POR IMAGEM Ano de publicação: 2015 Tipo de documento: Article País de afiliação: Reino Unido

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Processamento de Imagem Assistida por Computador / Imageamento por Ressonância Magnética / Siderose / Ferro / Cardiomiopatias / Miocárdio Tipo de estudo: Observational_studies / Prognostic_studies / Risk_factors_studies Limite: Adult / Female / Humans / Male / Middle aged Idioma: En Revista: J Cardiovasc Magn Reson Assunto da revista: ANGIOLOGIA / CARDIOLOGIA / DIAGNOSTICO POR IMAGEM Ano de publicação: 2015 Tipo de documento: Article País de afiliação: Reino Unido