Quantifying the impact of traffic-related air pollution on the indoor air quality of a naturally ventilated building.
Tong, Zheming; Chen, Yujiao; Malkawi, Ali; Adamkiewicz, Gary; Spengler, John D.
Afiliação
  • Tong Z; Center for Green Buildings and Cities, Graduate School of Design, Harvard University, Cambridge, MA 02138, USA. Electronic address: ztong@gsd.harvard.edu.
  • Chen Y; Center for Green Buildings and Cities, Graduate School of Design, Harvard University, Cambridge, MA 02138, USA.
  • Malkawi A; Center for Green Buildings and Cities, Graduate School of Design, Harvard University, Cambridge, MA 02138, USA.
  • Adamkiewicz G; Department of Environmental Health, Harvard T.H. Chan School of Public Health, Boston, MA 02115, USA.
  • Spengler JD; Department of Environmental Health, Harvard T.H. Chan School of Public Health, Boston, MA 02115, USA.
Environ Int ; 89-90: 138-46, 2016.
Article em En | MEDLINE | ID: mdl-26829764
ABSTRACT
Improper natural ventilation practices may deteriorate indoor air quality when in close proximity to roadways, although the intention is often to reduce energy consumption. In this study, we employed a CFD-based air quality model to quantify the impact of traffic-related air pollution on the indoor air quality of a naturally ventilated building. Our study found that the building envelope restricts dispersion and dilution of particulate matter. The indoor concentration in the baseline condition located 10m away from the roadway is roughly 16-21% greater than that at the edge of the roadway. The indoor flow recirculation creates a well-mixed zone with little variation in fine particle concentration (i.e., 253nm). For ultrafine particles (<100nm), a noticeable decrease in particle concentrations indoors with increasing distance from the road is observed due to Brownian and turbulent diffusion. In addition, the indoor concentration strongly depends on the distance between the roadway and building, particle size, wind condition, and window size and location. A break-even point is observed at D'~2.1 (normalized distance from the roadway by the width of the road). The indoor particle concentration is greater than that at the highway where D'<2.1, and vice versa. For new building planning, the distance from the roadway and the ambient wind condition need to be considered at the early design stage whereas the size and location of the window openings, the interior layout, and the placement of fresh air intakes are important to the indoor air quality of existing buildings adjacent to roadways.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Emissões de Veículos / Monitoramento Ambiental / Poluição do Ar em Ambientes Fechados / Poluentes Atmosféricos / Material Particulado / Modelos Teóricos Idioma: En Revista: Environ Int Ano de publicação: 2016 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Emissões de Veículos / Monitoramento Ambiental / Poluição do Ar em Ambientes Fechados / Poluentes Atmosféricos / Material Particulado / Modelos Teóricos Idioma: En Revista: Environ Int Ano de publicação: 2016 Tipo de documento: Article