Your browser doesn't support javascript.
loading
Use of computed tomography assessed kidney length to predict split renal GFR in living kidney donors.
Gaillard, François; Pavlov, Patrik; Tissier, Anne-Marie; Harache, Benoit; Eladari, Dominique; Timsit, Marc-Olivier; Fournier, Catherine; Léon, Carine; Hignette, Chantal; Friedlander, Gérard; Correas, Jean-Michel; Weinmann, Pierre; Méjean, Arnaud; Houillier, Pascal; Legendre, Christophe; Courbebaisse, Marie.
Afiliação
  • Gaillard F; AP-HP, Hôpital Necker-Enfants Malades, Renal Transplantation Department, Paris Descartes University, Paris, France. gaillard-francois@hotmail.fr.
  • Pavlov P; Linköping University, Linköping, Sweden.
  • Tissier AM; AP-HP, Hôpital Necker-Enfants Malades, Radiology Department, Paris Descartes University, Paris, France.
  • Harache B; AP-HP, Hôpital Européen Georges Pompidou, Nuclear Medicine Department, Paris Descartes University, Paris, France.
  • Eladari D; AP-HP, Hôpital Européen Georges Pompidou, Physiology Department, Paris Descartes University, and INSERM, Unit 970, Paris, France.
  • Timsit MO; AP-HP, Hôpital Européen Georges Pompidou, Urology Department, Paris Descartes University, Paris, France.
  • Fournier C; AP-HP, Hôpital Necker-Enfants Malades, Renal Transplantation Department, Paris Descartes University, Paris, France.
  • Léon C; AP-HP, Hôpital Necker-Enfants Malades, Renal Transplantation Department, Paris Descartes University, Paris, France.
  • Hignette C; AP-HP, Hôpital Européen Georges Pompidou, Nuclear Medicine Department, Paris Descartes University, Paris, France.
  • Friedlander G; AP-HP, Hôpital Européen Georges Pompidou, Physiology Department, Paris Descartes University, and INSERM, Unit 1151, Paris, France.
  • Correas JM; AP-HP, Hôpital Necker-Enfants Malades, Radiology Department, Paris Descartes University, Paris, France.
  • Weinmann P; AP-HP, Hôpital Européen Georges Pompidou, Nuclear Medicine Department, Paris Descartes University, Paris, France.
  • Méjean A; AP-HP, Hôpital Européen Georges Pompidou, Urology Department, Paris Descartes University, Paris, France.
  • Houillier P; AP-HP, Hôpital Européen Georges Pompidou, Physiology Department, Paris Descartes University, INSERM, Unit umrs1138, and CNRS Unit erl8228, Paris, France.
  • Legendre C; AP-HP, Hôpital Necker-Enfants Malades, Renal Transplantation Department, Paris Descartes University, Paris, France.
  • Courbebaisse M; AP-HP, Hôpital Européen Georges Pompidou, Physiology Department, Paris Descartes University, and INSERM, Unit 1151, Paris, France.
Eur Radiol ; 27(2): 651-659, 2017 Feb.
Article em En | MEDLINE | ID: mdl-27221559
ABSTRACT

OBJECTIVES:

Screening of living kidney donors may require scintigraphy to split glomerular filtration rate (GFR). To determine the usefulness of computed tomography (CT) to split GFR, we compared scintigraphy-split GFR to CT-split GFR. We evaluated CT-split GFR as a screening test to detect scintigraphy-split GFR lower than 40 mL/min/1.73 m2/kidney.

METHODS:

This was a monocentric retrospective study on 346 potential living donors who had GFR measurement, renal scintigraphy, and CT. We predicted GFR for each kidney by splitting GFR using the following formula Volume-split GFR for a given kidney = measured GFR*[volume of this kidney/(volume of this kidney + volume of the opposite kidney)]. The same formula was used for length-split GFR. We compared length- and volume-split GFR to scintigraphy-split GFR at donation and with a 4-year follow-up.

RESULTS:

A better correlation was observed between length-split GFR and scintigraphy-split GFR (r = 0.92) than between volume-split GFR and scintigraphy-split GFR (r = 0.89). A length-split GFR threshold of 45 mL/min/1.73 m2/kidney had a sensitivity of 100 % and a specificity of 75 % to detect scintigraphy-split GFR less than 40 mL/min/1.73 m2/kidney. Both techniques with their respective thresholds detected living donors with similar eGFR evolution during follow-up.

CONCLUSION:

Length-split GFR can be used to detect patients requiring scintigraphy. KEY POINTS • Excellent correlation between kidney length and scintigraphy predicted GFR • Kidney length screening detects all donors with GFR lower than 40 mL/min/1.73 m 2 • Kidney length screening can replace scintigraphy screening.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Tomografia Computadorizada por Raios X / Transplante de Rim / Doadores Vivos / Taxa de Filtração Glomerular / Rim Tipo de estudo: Diagnostic_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Limite: Female / Humans / Male / Middle aged Idioma: En Revista: Eur Radiol Assunto da revista: RADIOLOGIA Ano de publicação: 2017 Tipo de documento: Article País de afiliação: França

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Tomografia Computadorizada por Raios X / Transplante de Rim / Doadores Vivos / Taxa de Filtração Glomerular / Rim Tipo de estudo: Diagnostic_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Limite: Female / Humans / Male / Middle aged Idioma: En Revista: Eur Radiol Assunto da revista: RADIOLOGIA Ano de publicação: 2017 Tipo de documento: Article País de afiliação: França