Your browser doesn't support javascript.
loading
Carotid Intima-Media Thickness Manual Measurements: Intraoperator and Interoperator Agreements Under A Strict Protocol in a Large Sample.
Plasencia-Martínez, Juana M; García-Santos, José María; Lozano-Herrero, Jesús; Hernández-Vidal, M Julia.
Afiliação
  • Plasencia-Martínez JM; Departments of *Radiology and †Internal Medicine, Hospital General Universitario José M. Morales Meseguer, Murcia, Spain.
Ultrasound Q ; 33(1): 28-36, 2017 Mar.
Article em En | MEDLINE | ID: mdl-27575841
ABSTRACT

PURPOSE:

The aim of this study was to assess the intraoperator and interoperator agreement for manual measurements of intima-media thickness (IMT) performed under a strict carotid ultrasound technical protocol.

METHODS:

Two blinded experienced operators independently performed an ultrasound examination at the distal common carotid of 242 subjects in the same patient's position, diastolic phase, probe type, zooming, and depth. Thirty-six subjects were reevaluated in another time point. Three different-angle manual measurements (IMTindiv) were obtained. Interoperator agreements for each IMTindiv, and their mean (IMTmean) and maximum (IMTmax) values, were assessed with the intraclass correlation coefficient and Bland-Altman analysis. Intraoperator agreement was tested taking advantage of the second ultrasound round in 36 subjects.

RESULTS:

IMTmean agreements (intraoperator, 0.665-0.913; interoperator, 0.856-0.897) were higher than IMTmax (intraoperator, 0.435-0.793; interoperator, 0.631-0.718) and any IMTindiv (intraoperator, 0.355-0.676; interoperator, 0.590-0.717). Despite the small systematic error for IMTmean (intraoperator, ≤0.03; interoperator, ≤0.02 mm), at best of times, the sampling error size reached at least 0.28 and 0.25 mm for intraoperator and interoperator agreements, respectively, and was never less than 0.13 mm.

CONCLUSIONS:

Although IMTmean agreement is excellent under a strict protocol, limits of agreement might be too wide to consider carotid ultrasound a robust cardiovascular risk biomarker.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Variações Dependentes do Observador / Ultrassonografia / Aterosclerose / Espessura Intima-Media Carotídea Tipo de estudo: Diagnostic_studies / Etiology_studies / Risk_factors_studies Limite: Adult / Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Revista: Ultrasound Q Assunto da revista: DIAGNOSTICO POR IMAGEM Ano de publicação: 2017 Tipo de documento: Article País de afiliação: Espanha

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Variações Dependentes do Observador / Ultrassonografia / Aterosclerose / Espessura Intima-Media Carotídea Tipo de estudo: Diagnostic_studies / Etiology_studies / Risk_factors_studies Limite: Adult / Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Revista: Ultrasound Q Assunto da revista: DIAGNOSTICO POR IMAGEM Ano de publicação: 2017 Tipo de documento: Article País de afiliação: Espanha