Your browser doesn't support javascript.
loading
Use of pattern recognition for unaliasing simultaneously acquired slices in simultaneous multislice MR fingerprinting.
Jiang, Yun; Ma, Dan; Bhat, Himanshu; Ye, Huihui; Cauley, Stephen F; Wald, Lawrence L; Setsompop, Kawin; Griswold, Mark A.
Afiliação
  • Jiang Y; Department of Biomedical Engineering, Case Western Reserve University, Cleveland, Ohio, USA.
  • Ma D; Department of Radiology, Case Western Reserve University, Cleveland, Ohio, USA.
  • Bhat H; Siemens Medical Solutions USA Inc, Charlestown, Massachusetts, USA.
  • Ye H; Department of Radiology, Massachusetts General Hospital, Athinoula A. Martinos Center for Biomedical Imaging, Charlestown, Massachusetts, USA.
  • Cauley SF; Department of Biomedical Engineering, Zhejiang University, Hangzhou, Zhejiang, China.
  • Wald LL; Department of Radiology, Massachusetts General Hospital, Athinoula A. Martinos Center for Biomedical Imaging, Charlestown, Massachusetts, USA.
  • Setsompop K; Department of Radiology, Massachusetts General Hospital, Athinoula A. Martinos Center for Biomedical Imaging, Charlestown, Massachusetts, USA.
  • Griswold MA; Department of Electrical Engineering and Computer Science, Harvard-MIT Division of Health Sciences and Technology, MIT, Cambridge, Massachusetts, USA.
Magn Reson Med ; 78(5): 1870-1876, 2017 11.
Article em En | MEDLINE | ID: mdl-28019022
ABSTRACT

PURPOSE:

The purpose of this study is to accelerate an MR fingerprinting (MRF) acquisition by using a simultaneous multislice method.

METHODS:

A multiband radiofrequency (RF) pulse was designed to excite two slices with different flip angles and phases. The signals of two slices were driven to be as orthogonal as possible. The mixed and undersampled MRF signal was matched to two dictionaries to retrieve T1 and T2 maps of each slice. Quantitative results from the proposed method were validated with the gold-standard spin echo methods in a phantom. T1 and T2 maps of in vivo human brain from two simultaneously acquired slices were also compared to the results of fast imaging with steady-state precession based MRF method (MRF-FISP) with a single-band RF excitation.

RESULTS:

The phantom results showed that the simultaneous multislice imaging MRF-FISP method quantified the relaxation properties accurately compared to the gold-standard spin echo methods. T1 and T2 values of in vivo brain from the proposed method also matched the results from the normal MRF-FISP acquisition.

CONCLUSION:

T1 and T2 values can be quantified at a multiband acceleration factor of two using our proposed acquisition even in a single-channel receive coil. Further acceleration could be achieved by combining this method with parallel imaging or iterative reconstruction. Magn Reson Med 781870-1876, 2017. © 2016 International Society for Magnetic Resonance in Medicine.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Processamento de Imagem Assistida por Computador / Reconhecimento Automatizado de Padrão / Imageamento por Ressonância Magnética Limite: Humans Idioma: En Revista: Magn Reson Med Assunto da revista: DIAGNOSTICO POR IMAGEM Ano de publicação: 2017 Tipo de documento: Article País de afiliação: Estados Unidos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Processamento de Imagem Assistida por Computador / Reconhecimento Automatizado de Padrão / Imageamento por Ressonância Magnética Limite: Humans Idioma: En Revista: Magn Reson Med Assunto da revista: DIAGNOSTICO POR IMAGEM Ano de publicação: 2017 Tipo de documento: Article País de afiliação: Estados Unidos