Your browser doesn't support javascript.
loading
Load-induced changes in the diffusion tensor of ovine anulus fibrosus: A pilot MRI study.
Tourell, Monique C; Kirkwood, Margaret; Pearcy, Mark J; Momot, Konstantin I; Little, J Paige.
Afiliação
  • Tourell MC; School of Chemistry, Physics and Mechanical Engineering, Queensland University of Technology, Brisbane, Australia.
  • Kirkwood M; School of Chemistry, Physics and Mechanical Engineering, Queensland University of Technology, Brisbane, Australia.
  • Pearcy MJ; Paediatric Spine Research Group, Centre for Children's Health Research @ IHBI, School of Chemistry, Physics and Mechanical Engineering, Queensland University of Technology, Brisbane, Australia.
  • Momot KI; School of Chemistry, Physics and Mechanical Engineering, Queensland University of Technology, Brisbane, Australia.
  • Little JP; Paediatric Spine Research Group, Centre for Children's Health Research @ IHBI, School of Chemistry, Physics and Mechanical Engineering, Queensland University of Technology, Brisbane, Australia.
J Magn Reson Imaging ; 45(6): 1723-1735, 2017 06.
Article em En | MEDLINE | ID: mdl-28500665
ABSTRACT

PURPOSE:

To assess the feasibility of diffusion tensor imaging (DTI) for evaluating changes in anulus fibrosus (AF) microstructure following uniaxial compression. MATERIALS AND

METHODS:

Six axially aligned samples of AF were obtained from a merino sheep disc; two each from the anterior, lateral, and posterior regions. The samples were mechanically loaded in axial compression during five cycles at a rate and maximum compressive strain that reflected physiological conditions. DTI was conducted at 7T for each sample before and after mechanical testing.

RESULTS:

The mechanical response of all samples in unconfined compression was nonlinear. A stiffer response during the first loading cycle, compared to the remaining cycles, was observed. Change in diffusion parameters appeared to be region-dependent. The mean fractional anisotropy increased following mechanical testing. This was smallest in the lateral (2% and 9%) and largest in the anterior and posterior samples (17-25%). The mean average diffusivity remained relatively constant (<2%) after mechanical testing in the lateral and posterior samples, but increased (by 5%) in the anterior samples. The mean angle made by the principal eigenvector with the spine axis in the lateral samples was 73° and remained relatively constant (<2%) following mechanical testing. This angle was smaller in the anterior (55°) and posterior (47°) regions and increased by 6-16° following mechanical testing.

CONCLUSION:

These preliminary results suggest that axial compression reorients the collagen fibers, such that they become more consistently aligned parallel to the plane of the endplates. LEVEL OF EVIDENCE 1 Technical Efficacy Stage 1 J. MAGN. RESON. IMAGING 2017;451723-1735.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Interpretação de Imagem Assistida por Computador / Suporte de Carga / Imagem de Tensor de Difusão / Anel Fibroso Tipo de estudo: Diagnostic_studies Limite: Animals Idioma: En Revista: J Magn Reson Imaging Assunto da revista: DIAGNOSTICO POR IMAGEM Ano de publicação: 2017 Tipo de documento: Article País de afiliação: Austrália

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Interpretação de Imagem Assistida por Computador / Suporte de Carga / Imagem de Tensor de Difusão / Anel Fibroso Tipo de estudo: Diagnostic_studies Limite: Animals Idioma: En Revista: J Magn Reson Imaging Assunto da revista: DIAGNOSTICO POR IMAGEM Ano de publicação: 2017 Tipo de documento: Article País de afiliação: Austrália