Your browser doesn't support javascript.
loading
Screen-printed ambulatory electrode set enables accurate diagnostics of sleep bruxism.
Miettinen, Tomi; Myllymaa, Katja; Muraja-Murro, Anu; Westeren-Punnonen, Susanna; Hukkanen, Taina; Töyräs, Juha; Lappalainen, Reijo; Mervaala, Esa; Sipilä, Kirsi; Myllymaa, Sami.
Afiliação
  • Miettinen T; Department of Applied Physics, University of Eastern Finland, Kuopio, Finland.
  • Myllymaa K; Institute of Dentistry, University of Eastern Finland, Kuopio, Finland.
  • Muraja-Murro A; Diagnostic Imaging Center, Kuopio University Hospital, Kuopio, Finland.
  • Westeren-Punnonen S; Department of Applied Physics, University of Eastern Finland, Kuopio, Finland.
  • Hukkanen T; Diagnostic Imaging Center, Kuopio University Hospital, Kuopio, Finland.
  • Töyräs J; Diagnostic Imaging Center, Kuopio University Hospital, Kuopio, Finland.
  • Lappalainen R; Diagnostic Imaging Center, Kuopio University Hospital, Kuopio, Finland.
  • Mervaala E; Diagnostic Imaging Center, Kuopio University Hospital, Kuopio, Finland.
  • Sipilä K; Department of Applied Physics, University of Eastern Finland, Kuopio, Finland.
  • Myllymaa S; Diagnostic Imaging Center, Kuopio University Hospital, Kuopio, Finland.
J Sleep Res ; 27(1): 103-112, 2018 02.
Article em En | MEDLINE | ID: mdl-28513083
ABSTRACT
Currently, definite diagnosis of sleep bruxism requires polysomnography. However, it is restrictedly available, and too cumbersome and expensive for the purpose. The aim of this study was to introduce an ambulatory electrode set and evaluate its feasibility for more cost-effective diagnostics of sleep bruxism. Six self-assessed bruxers (one male, five females; aged 21-58 years) and six healthy controls (four males, two females, aged 21-25 years) underwent a standard polysomnographic study and a concurrent study with the ambulatory electrode set. Bruxism events, cortical arousals and sleep stages were scored for the two montages separately in a random order, and obtained sleep parameters were compared. In addition, the significance of video recording and sleep stage scoring for the diagnostic accuracy of ambulatory electrode set was determined. Ambulatory electrode set yielded similar diagnoses as standard polysomnography in all subjects. However, compared with standard polysomnography the median (interquartile range) tonic bruxism event index was significantly higher in the control group [+0.38 (+0.08 to +0.56) events per hour, P = 0.046], and the phasic bruxism event index was significantly lower in the bruxer group [-0.44 (-1.30 to +0.07) events per hour, P = 0.046]. Exclusion of video recording and both video recording and sleep stage scoring from analysis increased overestimation of the tonic bruxism event index in the control group +0.86 (+0.42 to +1.03) and +1.19 (+0.55 to +1.39) events per hour, P = 0.046 and P = 0.028, respectively], resulting in one misdiagnosed control subject. To conclude, ambulatory electrode set is a sensitive method for ambulatory diagnostics of sleep bruxism, and video recording and sleep stage scoring help reaching the highest specificity of sleep bruxism diagnostics.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Gravação em Vídeo / Bruxismo do Sono / Eletrodos Tipo de estudo: Diagnostic_studies Limite: Adult / Female / Humans / Male / Middle aged Idioma: En Revista: J Sleep Res Assunto da revista: PSICOFISIOLOGIA Ano de publicação: 2018 Tipo de documento: Article País de afiliação: Finlândia

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Gravação em Vídeo / Bruxismo do Sono / Eletrodos Tipo de estudo: Diagnostic_studies Limite: Adult / Female / Humans / Male / Middle aged Idioma: En Revista: J Sleep Res Assunto da revista: PSICOFISIOLOGIA Ano de publicação: 2018 Tipo de documento: Article País de afiliação: Finlândia