Ultra-fast LC-MS/MS in therapeutic drug monitoring: Quantification of clozapine and norclozapine in human plasma.
Couchman, Lewis; Fisher, Danielle S; Subramaniam, Krithika; Handley, Simon A; Boughtflower, Robert J; Benton, Christopher M; Flanagan, Robert J.
Afiliação
  • Couchman L; Viapath Analytics, Toxicology Unit, Department of Clinical Biochemistry, King's College Hospital NHS Foundation Trust, London, UK.
  • Fisher DS; Pharmaceutical Sciences Clinical Academic Group, King's College London, London, UK.
  • Subramaniam K; Viapath Analytics, Toxicology Unit, Department of Clinical Biochemistry, King's College Hospital NHS Foundation Trust, London, UK.
  • Handley SA; Viapath Analytics, Toxicology Unit, Department of Clinical Biochemistry, King's College Hospital NHS Foundation Trust, London, UK.
  • Boughtflower RJ; Viapath Analytics, Toxicology Unit, Department of Clinical Biochemistry, King's College Hospital NHS Foundation Trust, London, UK.
  • Benton CM; GSK, Hertfordshire, UK.
  • Flanagan RJ; Agilent Technologies Ltd., Cheshire, UK.
Drug Test Anal ; 10(2): 323-329, 2018 Feb.
Article em En | MEDLINE | ID: mdl-28585411
A novel approach to high-throughput, targeted liquid chromatography-tandem mass spectrometry (LC-MS/MS) analysis has been developed. A single chromatographic system can be used for the analysis of a range of 20 drugs and metabolites with a total analysis time of 36 s (one 96-well plate of prepared samples per hour). To demonstrate the applicability of this approach to quantitative analysis, a method has been validated for the therapeutic drug monitoring of clozapine and norclozapine following automated extraction from human plasma. Chromatographic retention times were 11.4 and 12.4 s for norclozapine and clozapine, respectively (for both analytes the chromatographic peak width was less than 1 s). Comparison with a conventional LC-MS/MS method (5 min analysis time) showed excellent agreement. This new approach offers analysis times more akin to flow-injection analysis, but is likely to be more widely applicable because of chromatographic resolution from residual matrix components and isobaric interferences.