Your browser doesn't support javascript.
loading
Randomized Comparison of 3 High-Level Disinfection and Sterilization Procedures for Duodenoscopes.
Snyder, Graham M; Wright, Sharon B; Smithey, Anne; Mizrahi, Meir; Sheppard, Michelle; Hirsch, Elizabeth B; Chuttani, Ram; Heroux, Riley; Yassa, David S; Olafsdottir, Lovisa B; Davis, Roger B; Anastasiou, Jiannis; Bapat, Vijay; Bidari, Kiran; Pleskow, Douglas K; Leffler, Daniel; Lane, Benjamin; Chen, Alice; Gold, Howard S; Bartley, Anthony; King, Aleah D; Sawhney, Mandeep S.
Afiliação
  • Snyder GM; Division of Infection Control/Hospital Epidemiology, Beth Israel Deaconess Medical Center, Boston, Massachusetts; Harvard Medical School, Boston, Massachusetts.
  • Wright SB; Division of Infection Control/Hospital Epidemiology, Beth Israel Deaconess Medical Center, Boston, Massachusetts; Harvard Medical School, Boston, Massachusetts.
  • Smithey A; Division of Infection Control/Hospital Epidemiology, Beth Israel Deaconess Medical Center, Boston, Massachusetts; Department of Pharmacy and Health Systems Sciences, Northeastern University, Boston, Massachusetts.
  • Mizrahi M; Division of Gastroenterology, Beth Israel Deaconess Medical Center, Boston, Massachusetts.
  • Sheppard M; Division of Gastroenterology, Beth Israel Deaconess Medical Center, Boston, Massachusetts.
  • Hirsch EB; Department of Pharmacy and Health Systems Sciences, Northeastern University, Boston, Massachusetts.
  • Chuttani R; Harvard Medical School, Boston, Massachusetts; Division of Gastroenterology, Beth Israel Deaconess Medical Center, Boston, Massachusetts.
  • Heroux R; Division of Infection Control/Hospital Epidemiology, Beth Israel Deaconess Medical Center, Boston, Massachusetts; Department of Pharmacy and Health Systems Sciences, Northeastern University, Boston, Massachusetts.
  • Yassa DS; Division of Infection Control/Hospital Epidemiology, Beth Israel Deaconess Medical Center, Boston, Massachusetts; Harvard Medical School, Boston, Massachusetts.
  • Olafsdottir LB; Division of Infection Control/Hospital Epidemiology, Beth Israel Deaconess Medical Center, Boston, Massachusetts.
  • Davis RB; Division of General Medicine and Primary Care, Beth Israel Deaconess Medical Center, Boston, Massachusetts.
  • Anastasiou J; Division of Gastroenterology, Beth Israel Deaconess Medical Center, Boston, Massachusetts.
  • Bapat V; Division of Gastroenterology, Beth Israel Deaconess Medical Center, Boston, Massachusetts.
  • Bidari K; Division of Gastroenterology, Beth Israel Deaconess Medical Center, Boston, Massachusetts.
  • Pleskow DK; Harvard Medical School, Boston, Massachusetts; Division of Gastroenterology, Beth Israel Deaconess Medical Center, Boston, Massachusetts.
  • Leffler D; Harvard Medical School, Boston, Massachusetts; Division of Gastroenterology, Beth Israel Deaconess Medical Center, Boston, Massachusetts.
  • Lane B; Division of Infection Control/Hospital Epidemiology, Beth Israel Deaconess Medical Center, Boston, Massachusetts.
  • Chen A; Division of Infection Control/Hospital Epidemiology, Beth Israel Deaconess Medical Center, Boston, Massachusetts; Department of Pharmacy and Health Systems Sciences, Northeastern University, Boston, Massachusetts.
  • Gold HS; Division of Infection Control/Hospital Epidemiology, Beth Israel Deaconess Medical Center, Boston, Massachusetts; Harvard Medical School, Boston, Massachusetts.
  • Bartley A; Division of Gastroenterology, Beth Israel Deaconess Medical Center, Boston, Massachusetts.
  • King AD; Division of Infection Control/Hospital Epidemiology, Beth Israel Deaconess Medical Center, Boston, Massachusetts.
  • Sawhney MS; Harvard Medical School, Boston, Massachusetts; Division of Gastroenterology, Beth Israel Deaconess Medical Center, Boston, Massachusetts. Electronic address: msawhney@bidmc.harvard.edu.
Gastroenterology ; 153(4): 1018-1025, 2017 10.
Article em En | MEDLINE | ID: mdl-28711629
ABSTRACT
BACKGROUND AND

AIMS:

Duodenoscopes have been implicated in the transmission of multidrug-resistant organisms (MDRO). We compared the frequency of duodenoscope contamination with MDRO or any other bacteria after disinfection or sterilization by 3 different methods.

METHODS:

We performed a single-center prospective randomized study in which duodenoscopes were randomly reprocessed by standard high-level disinfection (sHLD), double high-level disinfection (dHLD), or standard high-level disinfection followed by ethylene oxide gas sterilization (HLD/ETO). Samples were collected from the elevator mechanism and working channel of each duodenoscope and cultured before use. The primary outcome was the proportion of duodenoscopes with an elevator mechanism or working channel culture showing 1 or more MDRO; secondary outcomes included the frequency of duodenoscope contamination with more than 0 and 10 or more colony-forming units (CFU) of aerobic bacterial growth on either sampling location.

RESULTS:

After 3 months of enrollment, the study was closed because of the futility; we did not observe sufficient events to evaluate the primary outcome. Among 541 duodenoscope culture events, 516 were included in the final analysis. No duodenoscope culture in any group was positive for MDRO. Bacterial growth of more than 0 CFU was noted in 16.1% duodenoscopes in the sHLD group, 16.0% in the dHLD group, and 22.5% in the HLD/ETO group (P = .21). Bacterial growth or 10 or more CFU was noted in 2.3% of duodenoscopes in the sHLD group, 4.1% in the dHLD group, and 4.2% in the HLD/ETO group (P = .36). MRDOs were cultured from 3.2% of pre-procedure rectal swabs and 2.5% of duodenal aspirates.

CONCLUSIONS:

In a comparison of duodenoscopes reprocessed by sHLD, dHLD, or HLD/ETO, we found no significant differences between groups for MDRO or bacteria contamination. Enhanced disinfection methods (dHLD or HLD/ETO) did not provide additional protection against contamination. However, insufficient events occurred to assess our primary study end-point. ClinicalTrials.gov no NCT02611648.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: O-Ftalaldeído / Esterilização / Desinfecção / Infecção Hospitalar / Contaminação de Equipamentos / Duodenoscopia / Reutilização de Equipamento / Duodenoscópios / Farmacorresistência Bacteriana Múltipla / Desinfetantes Tipo de estudo: Clinical_trials / Observational_studies Limite: Humans Idioma: En Revista: Gastroenterology Ano de publicação: 2017 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: O-Ftalaldeído / Esterilização / Desinfecção / Infecção Hospitalar / Contaminação de Equipamentos / Duodenoscopia / Reutilização de Equipamento / Duodenoscópios / Farmacorresistência Bacteriana Múltipla / Desinfetantes Tipo de estudo: Clinical_trials / Observational_studies Limite: Humans Idioma: En Revista: Gastroenterology Ano de publicação: 2017 Tipo de documento: Article