Your browser doesn't support javascript.
loading
Quantifying the mode II critical strain energy release rate of borate bioactive glass coatings on Ti6Al4V substrates.
Matinmanesh, A; Li, Y; Clarkin, O; Zalzal, P; Schemitsch, E H; Towler, M R; Papini, M.
Afiliação
  • Matinmanesh A; Department of Mechanical and Industrial Engineering, Ryerson University, Toronto, Ontario, Canada M5B 2K3; St. Michael's Hospital, Toronto, Ontario, Canada M5B 1W8.
  • Li Y; Department of Mechanical and Industrial Engineering, Ryerson University, Toronto, Ontario, Canada M5B 2K3; St. Michael's Hospital, Toronto, Ontario, Canada M5B 1W8.
  • Clarkin O; Department of Mechanical and Manufacturing Engineering, Dublin City University, Dublin, Ireland.
  • Zalzal P; Oakville Trafalgar Memorial Hospital, Oakville, Ontario, Canada L6J 3L7.
  • Schemitsch EH; St. Michael's Hospital, Toronto, Ontario, Canada M5B 1W8.
  • Towler MR; Department of Mechanical and Industrial Engineering, Ryerson University, Toronto, Ontario, Canada M5B 2K3; St. Michael's Hospital, Toronto, Ontario, Canada M5B 1W8; Department of Biomedical Engineering, University of Malaya, Kuala Lumpur, Malaysia.
  • Papini M; Department of Mechanical and Industrial Engineering, Ryerson University, Toronto, Ontario, Canada M5B 2K3. Electronic address: mpapini@ryerson.ca.
J Mech Behav Biomed Mater ; 75: 212-221, 2017 11.
Article em En | MEDLINE | ID: mdl-28756281
ABSTRACT
Bioactive glasses have been used as coatings for biomedical implants because they can be formulated to promote osseointegration, antibacterial behavior, bone formation, and tissue healing through the incorporation and subsequent release of certain ions. However, shear loading on coated implants has been reported to cause the delamination and loosening of such coatings. This work uses a recently developed fracture mechanics testing methodology to quantify the critical strain energy release rate under nearly pure mode II conditions, GIIC, of a series of borate-based glass coating/Ti6Al4V alloy substrate systems. Incorporating increasing amounts of SrCO3 in the glass composition was found to increase the GIIC almost twofold, from 25.3 to 46.9J/m2. The magnitude and distribution of residual stresses in the coating were quantified, and it was found that the residual stresses in all cases distributed uniformly over the cross section of the coating. The crack was driven towards, but not into, the glass/Ti6Al4V substrate interface due to the shear loading. This implied that the interface had a higher fracture toughness than the coating itself.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Titânio / Boratos / Teste de Materiais / Materiais Revestidos Biocompatíveis / Vidro Idioma: En Revista: J Mech Behav Biomed Mater Assunto da revista: ENGENHARIA BIOMEDICA Ano de publicação: 2017 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Titânio / Boratos / Teste de Materiais / Materiais Revestidos Biocompatíveis / Vidro Idioma: En Revista: J Mech Behav Biomed Mater Assunto da revista: ENGENHARIA BIOMEDICA Ano de publicação: 2017 Tipo de documento: Article