Your browser doesn't support javascript.
loading
Monitoring chemical changes during food sterilisation using ultrahigh resolution mass spectrometry.
Marshall, James W; Schmitt-Kopplin, Philippe; Schuetz, Nadine; Moritz, Franco; Roullier-Gall, Chloé; Uhl, Jenny; Colyer, Alison; Jones, Lewis L; Rychlik, Michael; Taylor, Andrew J.
Afiliação
  • Marshall JW; WALTHAM Centre for Pet Nutrition, Mars Petcare, Waltham on the Wolds, Leicestershire LE14 4RT, United Kingdom. Electronic address: james.marshall@effem.com.
  • Schmitt-Kopplin P; Helmholtz Zentrum Muenchen, Analytical BioGeoChemistry, Ingolstaedter Landstr. 1, 85764 Neuherberg, Germany.
  • Schuetz N; WALTHAM Centre for Pet Nutrition, Mars Petcare, Waltham on the Wolds, Leicestershire LE14 4RT, United Kingdom.
  • Moritz F; Helmholtz Zentrum Muenchen, Analytical BioGeoChemistry, Ingolstaedter Landstr. 1, 85764 Neuherberg, Germany.
  • Roullier-Gall C; Helmholtz Zentrum Muenchen, Analytical BioGeoChemistry, Ingolstaedter Landstr. 1, 85764 Neuherberg, Germany.
  • Uhl J; Helmholtz Zentrum Muenchen, Analytical BioGeoChemistry, Ingolstaedter Landstr. 1, 85764 Neuherberg, Germany.
  • Colyer A; WALTHAM Centre for Pet Nutrition, Mars Petcare, Waltham on the Wolds, Leicestershire LE14 4RT, United Kingdom.
  • Jones LL; WALTHAM Centre for Pet Nutrition, Mars Petcare, Waltham on the Wolds, Leicestershire LE14 4RT, United Kingdom.
  • Rychlik M; Chair of Analytical Food Chemistry, Technical University of Munich, Alte Akademie 10, 85354 Freising, Germany.
  • Taylor AJ; WALTHAM Centre for Pet Nutrition, Mars Petcare, Waltham on the Wolds, Leicestershire LE14 4RT, United Kingdom.
Food Chem ; 242: 316-322, 2018 Mar 01.
Article em En | MEDLINE | ID: mdl-29037695
ABSTRACT
Sterilised food products undergo chemical changes during processing that ultimately determine the product quality. To provide detailed information on the chemistry of each stage of a pet-food sterilisation process, a laboratory-scale system was developed, which allowed sampling under the high temperatures and pressures associated with sterilisation. Products from the laboratory-scale system were representative of the factory process. Sample extracts were analysed by Fourier Transform-Ion Cyclotron Resonance-Mass Spectrometry (FT-ICR-MS), which delivered the molecular formulae and ion intensities of the compounds present. Data were examined to determine the coverage of this method, the degree of chemical change occurring during pet food thermal processing, and the level of identification possible with FT-ICR-MS. Data visualisation and statistical analysis identified significant chemical changes in pet food as a result of processing, and allowed tentative identification of the compounds involved. Insights generated using FT-ICR-MS analysis can be confirmed and further explored using conventional, targeted analyses.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Espectrometria de Massas / Pasteurização Tipo de estudo: Prognostic_studies Idioma: En Revista: Food Chem Ano de publicação: 2018 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Espectrometria de Massas / Pasteurização Tipo de estudo: Prognostic_studies Idioma: En Revista: Food Chem Ano de publicação: 2018 Tipo de documento: Article