Your browser doesn't support javascript.
loading
Calibration of imaging plate detectors to mono-energetic protons in the range 1-200 MeV.
Rabhi, N; Batani, D; Boutoux, G; Ducret, J-E; Jakubowska, K; Lantuejoul-Thfoin, I; Nauraye, C; Patriarca, A; Saïd, A; Semsoum, A; Serani, L; Thomas, B; Vauzour, B.
Afiliação
  • Rabhi N; CELIA (Centre Lasers Intenses et Applications), Université Bordeaux, CNRS, CEA, UMR 5107, F-33405 Talence, France.
  • Batani D; CELIA (Centre Lasers Intenses et Applications), Université Bordeaux, CNRS, CEA, UMR 5107, F-33405 Talence, France.
  • Boutoux G; CELIA (Centre Lasers Intenses et Applications), Université Bordeaux, CNRS, CEA, UMR 5107, F-33405 Talence, France.
  • Ducret JE; CELIA (Centre Lasers Intenses et Applications), Université Bordeaux, CNRS, CEA, UMR 5107, F-33405 Talence, France.
  • Jakubowska K; CELIA (Centre Lasers Intenses et Applications), Université Bordeaux, CNRS, CEA, UMR 5107, F-33405 Talence, France.
  • Lantuejoul-Thfoin I; CEA DAM DIF, F-91297 Arpajon, France.
  • Nauraye C; Institut Curie, Centre de Protonthérapie d'Orsay-Campus Universitaire, Bâtiment 101, 15, rue Georges Clémenceau, F-91898 Orsay Cedex, France.
  • Patriarca A; Institut Curie, Centre de Protonthérapie d'Orsay-Campus Universitaire, Bâtiment 101, 15, rue Georges Clémenceau, F-91898 Orsay Cedex, France.
  • Saïd A; Institut de Physique Nucléaire d'Orsay, 15, rue Georges Clémenceau, F-91405 Orsay Cedex, France.
  • Semsoum A; Institut de Physique Nucléaire d'Orsay, 15, rue Georges Clémenceau, F-91405 Orsay Cedex, France.
  • Serani L; Centre d'Etudes Nucléaires de Bordeaux Gradignan, Université de Bordeaux, UMR 5797 CNRS/IN2P3, 19, Chemin du Solarium, Gradignan F-33175, France.
  • Thomas B; Centre d'Etudes Nucléaires de Bordeaux Gradignan, Université de Bordeaux, UMR 5797 CNRS/IN2P3, 19, Chemin du Solarium, Gradignan F-33175, France.
  • Vauzour B; CEA DAM DIF, F-91297 Arpajon, France.
Rev Sci Instrum ; 88(11): 113301, 2017 Nov.
Article em En | MEDLINE | ID: mdl-29195357
ABSTRACT
Responses of Fuji Imaging Plates (IPs) to proton have been measured in the range 1-200 MeV. Mono-energetic protons were produced with the 15 MV ALTO-Tandem accelerator of the Institute of Nuclear Physics (Orsay, France) and, at higher energies, with the 200-MeV isochronous cyclotron of the Institut Curie-Centre de Protonthérapie d'Orsay (Orsay, France). The experimental setups are described and the measured photo-stimulated luminescence responses for MS, SR, and TR IPs are presented and compared to existing data. For the interpretation of the results, a sensitivity model based on the Monte Carlo GEANT4 code has been developed. It enables the calculation of the response functions in a large energy range, from 0.1 to 200 MeV. Finally, we show that our model reproduces accurately the response of more complex detectors, i.e., stack of high-Z filters and IPs, which could be of great interest for diagnostics of Petawatt laser accelerated particles.

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Prognostic_studies Idioma: En Revista: Rev Sci Instrum Ano de publicação: 2017 Tipo de documento: Article País de afiliação: França

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Prognostic_studies Idioma: En Revista: Rev Sci Instrum Ano de publicação: 2017 Tipo de documento: Article País de afiliação: França