Your browser doesn't support javascript.
loading
The determination of capreomycin in human plasma by LC-MS/MS using ion-pairing chromatography and solid-phase extraction.
Thuboy, Blessings; Kellermann, Tracy; Castel, Sandra; Norman, Jennifer; Joubert, Anton; Garcia-Prats, Anthony J; Hesseling, Anneke C; Wiesner, Lubbe.
Afiliação
  • Thuboy B; Pharmacy Department, College of Medicine, University of Malawi, Blantyre, Malawi.
  • Kellermann T; Division of Clinical Pharmacology, Department of Medicine, University of Cape Town, South Africa.
  • Castel S; Division of Clinical Pharmacology, Department of Medicine, University of Cape Town, South Africa.
  • Norman J; Division of Clinical Pharmacology, Department of Medicine, University of Cape Town, South Africa.
  • Joubert A; Division of Clinical Pharmacology, Department of Medicine, University of Cape Town, South Africa.
  • Garcia-Prats AJ; Division of Clinical Pharmacology, Department of Medicine, University of Cape Town, South Africa.
  • Hesseling AC; Desmond Tutu TB Centre, Department of Paediatrics and Child Health, Faculty of Medicine and Health Sciences, Stellenbosch University, Cape Town, South Africa.
  • Wiesner L; Desmond Tutu TB Centre, Department of Paediatrics and Child Health, Faculty of Medicine and Health Sciences, Stellenbosch University, Cape Town, South Africa.
Biomed Chromatogr ; : e4269, 2018 May 03.
Article em En | MEDLINE | ID: mdl-29726023
A bioanalytical method was developed and validated for the quantification of capreomycin (Cm) analogs, Cm IA and Cm IB, in human plasma. This implemented ion-pairing solid phase extraction, followed by ion-pairing high-performance liquid chromatography, with tandem mass spectrometry detection. Chromatographic separation was achieved using a Discovery C18 , 5 µm, 4.6 × 50 mm analytical column. An isocratic mobile phase consisting of water and acetonitrile with 0.1% formic acid and 4mm heptafluorobutyric acid (80:20; v/v) was used at a flow-rate of 500 µL/min. An AB Sciex API 3000 mass spectrometer at unit resolution, in multiple reaction monitoring mode, was used for detection. Electrospray ionization was used for ion production. The method was successfully validated for the range 469-30,000 ng/mL for Cm IA and for Cm IB, with cefotaxime as the internal standard. The within- and between-day precision determinations for Cm IA and IB, expressed as the percentage coefficient of variation, were < 20.0% at the lower limit of quantification (LLOQ) and < 8.2% at all other test concentrations. Recovery of both analogs was > 72.3% and reproducible at the low, medium and high end of the calibration range. No significant matrix effects were observed for the analyte. The assay performed well when applied to clinical samples generated from children in a clinical multidrug resistant tuberculosis research study in South Africa.