Your browser doesn't support javascript.
loading
Improved sensitivity and limit-of-detection using a receive-only coil in magnetic particle imaging.
Paysen, Hendrik; Wells, James; Kosch, Olaf; Steinhoff, Uwe; Franke, Jochen; Trahms, Lutz; Schaeffter, Tobias; Wiekhorst, Frank.
Afiliação
  • Paysen H; Physikalisch-Technische Bundesanstalt, Abbestrasse 2-12, 10587 Berlin, Germany.
Phys Med Biol ; 63(13): 13NT02, 2018 07 02.
Article em En | MEDLINE | ID: mdl-29888711
ABSTRACT
Magnetic particle imaging (MPI) is an imaging modality capable of quantitatively determining the 3D distribution of a magnetic nanoparticle (MNP) ensemble. In this work, we present a method for reducing the MNP limit of detection by employing a new receive-only coil (Rx-coil) for signal acquisition. The new signal detector is designed to improve the sensitivity and thus quality of reconstructed images. We present characterization measurements conducted with the prototype Rx-coil installed in a preclinical MPI scanner. The gradiometric design of the Rx-coil attenuates the unwanted signal contributions arising from the excitation field, leading to a 17 dB lower background level compared to the conventional dual-purpose coil (TxRx-coil), which is crucial for detecting low amounts of MNP. Network analyzer measurements of the frequency-dependent coil sensitivity, as well as spectral analysis of recorded MPI data demonstrate an overall increase of the coil sensitivity of about +12 dB for the Rx-coil. Comparisons of the sensitivity distributions revealed no significant degradations in terms of homogeneity for the Rx-coil compared to the TxRx-coil in an imaging volume of 6 × 3 × 3 cm3. Finally, the limit of detection was determined experimentally for each coil type using a serial dilution of MNPs, resulting in values of 133 ng of iron for the conventional TxRx-coil and 20 ng for the new Rx-coil, using an acquisition time of 2 s. A linear relationship between the reconstructed signal intensities and the iron mass in the samples was observed with coefficients of determination (R2) of above 99% in the range of the limit of detection to 3 103ng(Fe). These results open the way for improved image quality and faster acquisition time in pre-clinical MPI scanners.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Processamento de Imagem Assistida por Computador / Imageamento por Ressonância Magnética / Nanopartículas de Magnetita Tipo de estudo: Diagnostic_studies Limite: Humans Idioma: En Revista: Phys Med Biol Ano de publicação: 2018 Tipo de documento: Article País de afiliação: Alemanha

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Processamento de Imagem Assistida por Computador / Imageamento por Ressonância Magnética / Nanopartículas de Magnetita Tipo de estudo: Diagnostic_studies Limite: Humans Idioma: En Revista: Phys Med Biol Ano de publicação: 2018 Tipo de documento: Article País de afiliação: Alemanha