Your browser doesn't support javascript.
loading
Sheathless coupling of microchip electrophoresis to ESI-MS utilising an integrated photo polymerised membrane for electric contacting.
Scholl, T; Dietze, C; Schmidt, M; Ohla, S; Belder, D.
Afiliação
  • Scholl T; Institut für Analytische Chemie, Universität Leipzig, Johannisallee 29, 04103, Leipzig, Germany.
  • Dietze C; Institut für Analytische Chemie, Universität Leipzig, Johannisallee 29, 04103, Leipzig, Germany.
  • Schmidt M; Institut für Analytische Chemie, Universität Leipzig, Johannisallee 29, 04103, Leipzig, Germany.
  • Ohla S; Institut für Analytische Chemie, Universität Leipzig, Johannisallee 29, 04103, Leipzig, Germany.
  • Belder D; Institut für Analytische Chemie, Universität Leipzig, Johannisallee 29, 04103, Leipzig, Germany. Belder@uni-leipzig.de.
Anal Bioanal Chem ; 410(23): 5741-5750, 2018 Sep.
Article em En | MEDLINE | ID: mdl-29974150
ABSTRACT
In this article, we present a novel approach for the sheathless coupling of microchip electrophoresis (MCE) with electrospray mass spectrometry (ESI-MS). The key element is an ion-conductive hydrogel membrane, placed between the separation channel and an adjacent microfluidic supporting channel, contacted via platinum electrodes. This solves the persistent challenge in hyphenation of mass spectrometry to chip electrophoresis, to ensure a reliable electrical connection at the end of the electrophoresis channel without sacrificing separation performance and sensitivity. Stable electric contacting is achieved via a Y-shaped supporting channel structure, separated from the main channel by a photo polymerised, ion permeable hydrogel membrane. Thus, the potential gradient required for performing electrophoretic separations can be generated while simultaneously preventing gas formation due to electrolysis. In contrast to conventional make-up or sheathflow approaches, sample dilution is also avoided. Rapid prototyping allowed the study of different chip-based approaches, i.e. sheathless, open sheathflow and electrode support channel designs, for coupling MCE to ESI-MS. The performance was evaluated with fluorescence microscopy and mass spectrometric detection. The obtained results revealed that the detection sensitivity obtained in such Y-channel chips with integrated hydrogel membranes was superior because sample dilution or loss was prevented. Furthermore, band broadening is reduced compared to similar open structures without a membrane.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Anal Bioanal Chem Ano de publicação: 2018 Tipo de documento: Article País de afiliação: Alemanha

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Anal Bioanal Chem Ano de publicação: 2018 Tipo de documento: Article País de afiliação: Alemanha