Your browser doesn't support javascript.
loading
Comparison of ultrasound guidance with palpation and direct visualisation for peripheral vein cannulation in adult patients: a systematic review and meta-analysis.
van Loon, F H J; Buise, M P; Claassen, J J F; Dierick-van Daele, A T M; Bouwman, A R A.
Afiliação
  • van Loon FHJ; Department of Research and Education, Catharina Hospital, Eindhoven, The Netherlands; Department of Technical Nursing Education, Fontys University of Applied Sciences, Eindhoven, The Netherlands; Department of Anaesthesiology, Pain Medicine and Intensive Care, Catharina Hospital, Eindhoven, The Neth
  • Buise MP; Department of Anaesthesiology, Pain Medicine and Intensive Care, Catharina Hospital, Eindhoven, The Netherlands.
  • Claassen JJF; Department of Anaesthesiology, Pain Medicine and Intensive Care, Catharina Hospital, Eindhoven, The Netherlands.
  • Dierick-van Daele ATM; Department of Research and Education, Catharina Hospital, Eindhoven, The Netherlands; Department of Technical Nursing Education, Fontys University of Applied Sciences, Eindhoven, The Netherlands.
  • Bouwman ARA; Department of Anaesthesiology, Pain Medicine and Intensive Care, Catharina Hospital, Eindhoven, The Netherlands; Department of Signal Processing Systems and Electrical Engineering, TU/e University of Technology, Eindhoven, The Netherlands.
Br J Anaesth ; 121(2): 358-366, 2018 Aug.
Article em En | MEDLINE | ID: mdl-30032874
ABSTRACT

BACKGROUND:

Peripheral vein cannulation is a routine and straightforward invasive procedure, although i.v. access can be difficult to obtain. To increase the success rate of inserting an i.v. catheter, many devices have been proposed, including ultrasonography. The objective of this study was to compare ultrasound guidance with the traditional approach of palpation and direct visualisation for peripehral vein cannulation. The primary outcome was successful peripheral i.v. cannulation.

METHODS:

Database search was performed on PubMed, Clinical Key, CINAHL, Cochrane Library of Clinical Trials, and Trip Database (from January 2000 to December 2017). Random-effect meta-analysis was performed to determine the pooled odds ratio for success in peripheral i.v. cannulation.

RESULTS:

After database review and eligibility screening, eight studies were included in the final analysis, with a total of 1660 patients. The success rate in the ultrasound group was 81% (n=855), and was 70% (n=805) in the control group, resulting in a pooled odds ratio for success upon ultrasound-guided peripheral i.v. cannulation of 2.49 (95% confidence interval 1.37-4.52, P=0.003). Furthermore, the ultrasound-guided technique reduced the number of punctures and time needed to achieve i.v. access, and increased the level of patient satisfaction, although it did not result in a decreased number of complications.

CONCLUSIONS:

Ultrasound guidance increases the success rate of peripheral i.v. cannulation, especially in patients with known or predicted difficult i.v. access.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Veias / Cateterismo Periférico / Ultrassonografia de Intervenção Tipo de estudo: Guideline / Prognostic_studies / Systematic_reviews Limite: Adult / Humans Idioma: En Revista: Br J Anaesth Ano de publicação: 2018 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Veias / Cateterismo Periférico / Ultrassonografia de Intervenção Tipo de estudo: Guideline / Prognostic_studies / Systematic_reviews Limite: Adult / Humans Idioma: En Revista: Br J Anaesth Ano de publicação: 2018 Tipo de documento: Article