Non-invasive monitoring using photoplethysmography technology.
Tomita, Keisuke; Nakada, Taka-Aki; Oshima, Taku; Oami, Takehiko; Aizimu, Tuerxun; Oda, Shigeto.
Afiliação
  • Tomita K; Department of Emergency and Critical Care Medicine, Chiba University Graduate School of Medicine, 1-8-1 Inohana, Chuo, Chiba, 260-8677, Japan.
  • Nakada TA; Department of Emergency and Critical Care Medicine, Chiba University Graduate School of Medicine, 1-8-1 Inohana, Chuo, Chiba, 260-8677, Japan. taka.nakada@nifty.com.
  • Oshima T; Department of Emergency and Critical Care Medicine, Chiba University Graduate School of Medicine, 1-8-1 Inohana, Chuo, Chiba, 260-8677, Japan.
  • Oami T; Department of Emergency and Critical Care Medicine, Chiba University Graduate School of Medicine, 1-8-1 Inohana, Chuo, Chiba, 260-8677, Japan.
  • Aizimu T; Center for Frontier Medical Engineering, Chiba University, 1-8-1 Inohana, Chuo, Chiba, 260-8677, Japan.
  • Oda S; Department of Emergency and Critical Care Medicine, Chiba University Graduate School of Medicine, 1-8-1 Inohana, Chuo, Chiba, 260-8677, Japan.
J Clin Monit Comput ; 33(4): 637-645, 2019 Aug.
Article em En | MEDLINE | ID: mdl-30284687
ABSTRACT
We evaluated the accuracy and precision of a novel non-invasive monitoring device in comparison with conventional monitoring methods used in intensive care units (ICU). The study device was developed to measure blood pressure, pulse rate, respiratory rate, and oxygen saturation, continuously with a single sensor using the photoplethysmographic technique. Patients who were monitored with arterial pressure lines in the ICU were enrolled. Systolic and diastolic blood pressure, pulse rate, respiratory rate, and arterial oxygen saturation were measured continuously for 30 min at 5-min intervals using the conventional methods and the study device. The primary outcome variable was blood pressure. Blood pressure measured by the study device highly correlated with the arterial pressure line values (correlation coefficients > 0.95). Percent errors for systolic, diastolic and mean blood pressures were 2.4% and 6.7% and 6.5%, respectively. Percent errors for pulse rate, respiratory rate and oxygen saturation were 3.4%, 5.6% and 1.4%, respectively. The non-invasive, continuous, multi-parameter monitoring device presented high level of agreement with the invasive arterial blood pressure monitoring, along with sufficient accuracy and precision in the measurements of pulse rate, respiratory rate, and oxygen saturation.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Determinação da Pressão Arterial / Fotopletismografia Tipo de estudo: Observational_studies Limite: Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Revista: J Clin Monit Comput Assunto da revista: INFORMATICA MEDICA / MEDICINA Ano de publicação: 2019 Tipo de documento: Article País de afiliação: Japão

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Determinação da Pressão Arterial / Fotopletismografia Tipo de estudo: Observational_studies Limite: Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Revista: J Clin Monit Comput Assunto da revista: INFORMATICA MEDICA / MEDICINA Ano de publicação: 2019 Tipo de documento: Article País de afiliação: Japão