Your browser doesn't support javascript.
loading
Comparison of ultrasonic pachymetry and Fourier-domain optical coherence tomography for measurement of corneal thickness in dogs with and without corneal disease.
Hoehn, A L; Thomasy, S M; Kass, P H; Horikawa, T; Samuel, M; Shull, O R; Stewart, K A; Murphy, C J.
Afiliação
  • Hoehn AL; Department of Surgical and Radiological Sciences, School of Veterinary Medicine, University of California, Davis, One Shields Avenue, Davis, CA 95616, USA.
  • Thomasy SM; Department of Surgical and Radiological Sciences, School of Veterinary Medicine, University of California, Davis, One Shields Avenue, Davis, CA 95616, USA; Department of Ophthalmology & Vision Science, School of Medicine, University of California, Davis, 4610 X St., Sacramento, CA 95817, USA. El
  • Kass PH; Department of Population Health and Reproduction, School of Veterinary Medicine, University of California, Davis, One Shields Avenue, Davis, CA 95616, USA.
  • Horikawa T; Animal Eye Center, 5175 Pacific St., Rocklin, CA 95677, USA.
  • Samuel M; Eye Care for Animals, 21160 W. Capitol Drive Suite B, Pewaukee, WI 53072, USA.
  • Shull OR; Department of Surgical and Radiological Sciences, School of Veterinary Medicine, University of California, Davis, One Shields Avenue, Davis, CA 95616, USA.
  • Stewart KA; Department of Surgical and Radiological Sciences, School of Veterinary Medicine, University of California, Davis, One Shields Avenue, Davis, CA 95616, USA.
  • Murphy CJ; Department of Surgical and Radiological Sciences, School of Veterinary Medicine, University of California, Davis, One Shields Avenue, Davis, CA 95616, USA; Department of Ophthalmology & Vision Science, School of Medicine, University of California, Davis, 4610 X St., Sacramento, CA 95817, USA.
Vet J ; 242: 59-66, 2018 Dec.
Article em En | MEDLINE | ID: mdl-30503546
ABSTRACT
Several ultrasonic and Fourier-domain optical coherence tomography (FD-OCT) pachymeters are used to measure corneal thickness in canine patients and research subjects. This study assessed the reliability of and consistency between two ultrasonic pachymetry (USP) devices, Pachette 3 and Accupach VI, as well as automated and manual measurements obtained using FD-OCT in dogs with and without corneal disease. Corneal thickness measurements were compiled from 108 dogs and analyzed using mixed effects linear regression, with Bonferonni adjustments for post-hoc comparisons, to determine the effects of age, weight and disease state. Data are presented as predicted mean±standard error. Canine corneal disease can result in marked increases in thickness that frequently exceed the upper limits of measurement of some pachymetry devices developed for human use. In this study, the corneas of dogs with endothelial disease or injury frequently exceeded the upper limits of quantitation of 999 and 800µm for the Accupach VI and automated FD-OCT pachymeters, respectively. Using values <800µm, the Pachette 3 generated significantly greater values for central corneal thickness (CCT) than the Accupach VI, manual FD-OCT and automated FD-OCT at 625±7.0, 615±7.2, 613±7.2, and 606±7.4µm respectively (P<0.001). Of the two devices where measurements >1000µm were obtained, manual FD-OCT demonstrated less variability than the Pachette 3. Corneal thickness increased linearly with age and weight with an increase of 6.9±1.8µm/year and 1.6±0.8µm/kg body weight (P<0.005 and P=0.038, respectively).
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Córnea / Doenças da Córnea / Tomografia de Coerência Óptica / Doenças do Cão / Cães / Paquimetria Corneana Tipo de estudo: Observational_studies / Risk_factors_studies Limite: Animals Idioma: En Revista: Vet J Assunto da revista: MEDICINA VETERINARIA Ano de publicação: 2018 Tipo de documento: Article País de afiliação: Estados Unidos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Córnea / Doenças da Córnea / Tomografia de Coerência Óptica / Doenças do Cão / Cães / Paquimetria Corneana Tipo de estudo: Observational_studies / Risk_factors_studies Limite: Animals Idioma: En Revista: Vet J Assunto da revista: MEDICINA VETERINARIA Ano de publicação: 2018 Tipo de documento: Article País de afiliação: Estados Unidos