Characteristics of the Exradin W1 scintillator in the magnetic field.
Yoon, Jeongmin; Kim, Jung-In; Choi, Chang Heon; Park, Jong Min.
Afiliação
  • Yoon J; Department of Radiation Oncology, Seoul National University Hospital, Seoul, Korea.
  • Kim JI; Institute of Radiation Medicine, Seoul National University Medical Research Center, Seoul, Korea.
  • Choi CH; Biomedical Research Institute, Seoul National University College of Medicine, Seoul, Korea.
  • Park JM; Department of Radiation Oncology, Seoul National University Hospital, Seoul, Korea.
J Appl Clin Med Phys ; 20(9): 149-156, 2019 Sep.
Article em En | MEDLINE | ID: mdl-31460702
ABSTRACT
To investigate the angular dependency of the W1 scintillator with and without a magnetic field, the beam incidence angles to the detector varied from 0° to 360° at intervals of 30° when the detector was pointed in both the craniocaudal and right-to-left directions. The beam incidence angles also varied from 0° to 360° at intervals of 45° when the W1 scintillator was in the anterior-to-posterior direction. To investigate the field size dependency of the W1 scintillator with and without a magnetic field, the doses by an identical beam-on time were measured at various square field sizes and the measured doses were normalized to the dose at the field of 10.5 cm × 10.5 cm (FS10.5). With and without a magnetic field, the deviations of the doses to the dose at the beam incident angle of 0° were always less than 1% regardless of the dosimeter positioning relative to the magnetic field direction. When the field sizes were equal to or less than FS10.5, the differences in the output factors with and without a magnetic field were less than 0.7%. However, those were larger than 1% at fields larger than FS10.5, and up to 3.1%. The W1 scintillator showed no angular dependency to the magnetic field. Differences larger than 1% in the output factors with and without a magnetic field were observed at field sizes larger than 10.5 cm × 10.5 cm.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Aceleradores de Partículas / Contagem de Cintilação / Método de Monte Carlo / Fótons / Imagens de Fantasmas Tipo de estudo: Health_economic_evaluation Limite: Humans Idioma: En Revista: J Appl Clin Med Phys Assunto da revista: BIOFISICA Ano de publicação: 2019 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Aceleradores de Partículas / Contagem de Cintilação / Método de Monte Carlo / Fótons / Imagens de Fantasmas Tipo de estudo: Health_economic_evaluation Limite: Humans Idioma: En Revista: J Appl Clin Med Phys Assunto da revista: BIOFISICA Ano de publicação: 2019 Tipo de documento: Article