Your browser doesn't support javascript.
loading
D-shaped plastic optical fibre aptasensor for fast thrombin detection in nanomolar range.
Cennamo, Nunzio; Pasquardini, Laura; Arcadio, Francesco; Vanzetti, Lia E; Bossi, Alessandra Maria; Zeni, Luigi.
Afiliação
  • Cennamo N; Department of Engineering, University of Campania "L. Vanvitelli", Via Roma 29, Aversa, Italy.
  • Pasquardini L; Indivenire srl, Via Alla Cascata 56/C, 38123, Trento, Italy.
  • Arcadio F; Department of Engineering, University of Campania "L. Vanvitelli", Via Roma 29, Aversa, Italy.
  • Vanzetti LE; Fondazione Bruno Kessler-CMM-MNF, Via Sommarive 18, Trento, Italy.
  • Bossi AM; Department of Biotechnology, University of Verona, Cà Vignal 1, Strada Le Grazie 15, 37134, Verona, Italy. alessandramaria.bossi@univr.it.
  • Zeni L; Department of Engineering, University of Campania "L. Vanvitelli", Via Roma 29, Aversa, Italy. luigi.zeni@unicampania.it.
Sci Rep ; 9(1): 18740, 2019 12 10.
Article em En | MEDLINE | ID: mdl-31822733
ABSTRACT
The development of optical biosensors for the rapid and costless determination of clinical biomarkers is of paramount importance in medicine. Here we report a fast and low-cost biosensor based on a plasmonic D-shaped plastic optical fibre (POF) sensor derivatized with an aptamer specific for the recognition of thrombin, the target marker of blood homeostasis and coagulation cascade. In particular, we designed a functional interface based on a Self Assembled Monolayer (SAM) composed of short Poly Ethylene Glycol (PEG) chains and biotin-modified PEG thiol in ratio 82 molmol, these latter serving as baits for the binding of the aptamer through streptavidin-chemistry. The SAM was studied by X-ray Photoelectron Spectroscopy (XPS) analysis, static contact angle (CA), Surface Plasmon Resonance (SPR) in POFs, and fluorescence microscopy on gold surface. The optimized SAM composition enabled the immobilization of about 112 ng/cm2 of aptamer. The thrombin detection exploiting POF-Aptasensor occurred in short times (5-10 minutes), the reached Limit of Detection (LOD) was about 1 nM, and the detection range was 1.6-60 nM, indicating the POF-Aptasensor well addresses the needs for a low-cost, simple to use and to realize, rapid, small size and portable diagnostic platform.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Plásticos / Trombina / Técnicas Biossensoriais / Ressonância de Plasmônio de Superfície / Fibras Ópticas Tipo de estudo: Diagnostic_studies Idioma: En Revista: Sci Rep Ano de publicação: 2019 Tipo de documento: Article País de afiliação: Itália

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Plásticos / Trombina / Técnicas Biossensoriais / Ressonância de Plasmônio de Superfície / Fibras Ópticas Tipo de estudo: Diagnostic_studies Idioma: En Revista: Sci Rep Ano de publicação: 2019 Tipo de documento: Article País de afiliação: Itália