Your browser doesn't support javascript.
loading
Changes in the Physical Function and Psychological Distress from Pre-Implant to 1, 6, and 12 Months Post-Implant in Patients Undergoing Implantable Cardioverter Defibrillator Therapy.
Kim, JinShil; Park, Jin-Kyu; Choi, Jiin; Kim, Sun Hwa; On, Young Keun; Shin, Mi-Seung; Choi, NaYeon; Heo, Seongkum.
Afiliação
  • Kim J; College of Nursing (Medical campus), Gachon University, Incheon 21936, Korea.
  • Park JK; Division of Cardiology, Department of Internal Medicine, College of Medicine, Hanyang University, Seoul 04763, Korea.
  • Choi J; Office of Hospital Information, Seoul National University Hospital, Seoul 03080, Korea.
  • Kim SH; Department of Nursing, Hanyang University Medical Center, Seoul 04763, Korea.
  • On YK; Division of Cardiology, Department of Internal Medicine, Heart Vascular Stroke Institute, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul 06351, Korea.
  • Shin MS; Division of Cardiology, Department of Internal Medicine, Gil Medical Center, Gachon University, College of Medicine, Incheon 21936, Korea.
  • Choi N; Biostatistical Consulting and Research Lab, Medical Research Collaborating Center, Hanyang University, Seoul 04763, Korea.
  • Heo S; Georgia Baptist College of Nursing, Mercer University, Atlanta, GA 31207, USA.
J Clin Med ; 9(2)2020 Jan 22.
Article em En | MEDLINE | ID: mdl-31979074
ABSTRACT
Recipients of implantable cardioverter-defibrillator (ICD) therapy in Western countries often experience distressful physical and psychological adjustments. Sociocultural influences on post-implant recovery are likely; however, evidence from other ethnic/cultural backgrounds is lacking. This study aimed to examine the changes in physical function and psychological distress (anxiety and depressive symptoms) from pre-implant to one, six, and 12 months post-implant in Korean patients undergoing ICD therapy. A total of 34 patients underwent pre- to post-implant longitudinal assessments of physical and psychological function using mixed modeling procedures. Physical function significantly declined from pre-implant to one month post-implant (B = -10.05, p = 0.004) and then nearly returned to the pre-implant level at six months post-implant (B = 8.34, p = 0.028). This level of improvement continued through 12 months post-implant. In psychological distress, significant improvements were observed from pre-implant to one month (anxiety (B = -1.20, p = 0.020) and in depressive symptoms (B = -1.15, p = 0.037)), which then plateaued without significant changes from one to 12 months. We concluded that physical function recovery occurred six months post-implant, but function remained poor until 12 months post-implant. Psychological distress improved one month post-implant and it was maintained. Clinicians must provide more intensive interventions to improve long-term physical function after ICD therapy.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: J Clin Med Ano de publicação: 2020 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: J Clin Med Ano de publicação: 2020 Tipo de documento: Article