Your browser doesn't support javascript.
loading
Comparative study on the clinical application of mixed reality technology leading micro-invasive intervertebral foramen puncture location and blind puncture location.
Guo, Ma-Long; Yue, Song-Tao; Wang, Jiang-Yi; Cui, Hong-Xun.
Afiliação
  • Guo ML; Ma-long Guo, Department of Orthopedics, Orthopedic Hospital of Henan Province, Luoyang, Henan 471000, P.R. China.
  • Yue ST; Song-tao Yue, Department of Orthopedics, Orthopedic Hospital of Henan Province, Luoyang, Henan 471000, P.R. China.
  • Wang JY; Jiang-yi Wang, Department of Orthopedics, Orthopedic Hospital of Henan Province, Luoyang, Henan 471000, P.R. China.
  • Cui HX; Hong-xun Cui, Department of Orthopedics, Orthopedic Hospital of Henan Province, Luoyang, Henan 471000, P.R. China.
Pak J Med Sci ; 36(3): 559-564, 2020.
Article em En | MEDLINE | ID: mdl-32292471
ABSTRACT

OBJECTIVE:

To discuss the function of mixed reality (MR) technology in guiding location of intervertebral foramen microscopic puncture and analyze its feasibility and clinical application value.

METHODS:

Sixty patients with lumbar intervertebral disc who were treated between January 2017 to October 2017 were chosen, and classified into navigation group (30 cases) and traditional control (30 cases) according to random number table. Intervertebral foramen microscopic operation was conducted for both groups. MR technology was applied for the navigation group to guide puncture and establish intervertebral foramen microscopic cannula. Traditional C-arm X-ray apparatus was used for traditional group to establish intervertebral foramen microscopic cannula. Intra-operative puncture times, fluoroscopy times, puncture time and VAS score 1d, 3m and 6m after the operation were recorded and compared.

RESULTS:

Postoperative waist and leg pain symptoms of both groups were relieved obviously, and straight leg raising test for the diseased limb turned to be negative. Intra-operative puncture times, fluoroscopy times, puncture time and operation time had statistical significance decrease.

CONCLUSION:

Mixed reality (MR) can accurately guide the establishment of intervertebral foramen microscopic cannula, solve the bottleneck problem of intervertebral foramen microscopic technology, promote puncture success rate, reduce repeated puncture times, avoid by-injury, shorten puncture time and reduce X-ray radiation quantity of operators and patients, so it deserves to be promoted and applied.