Your browser doesn't support javascript.
loading
Ultrasonographic measurement of the adrenal gland in neonatal foals: reliability of the technique and assessment of variation in healthy foals during the first five days of life.
Lauteri, Eleonora; Mariella, Jole; Beccati, Francesca; De Graaf-Roelfsema, Ellen; Castagnetti, Carolina; Pepe, Marco; Peric, Tanja; Barbato, Olimpia; Montillo, Marta; Rouge, Stefanie; Freccero, Francesca.
Afiliação
  • Lauteri E; Department of Veterinary Medicine, University of Perugia, Perugia, Italy eleonoralauteri@gmail.com.
  • Mariella J; Clinèquine, VetAgro Sup, University of Lyon, Marcy-l'Etoile, France.
  • Beccati F; Department of Veterinary Medical Sciences, University of Bologna, Ozzano dell'Emilia, Emilia-Romagna, Italy.
  • De Graaf-Roelfsema E; Department of Veterinary Medicine, University of Perugia, Perugia, Italy.
  • Castagnetti C; Department of Equine Sciences, Faculty of Veterinary Medicine, Utrecht University, Utrecht, The Netherlands.
  • Pepe M; Department of Veterinary Medical Sciences, University of Bologna, Ozzano dell'Emilia, Emilia-Romagna, Italy.
  • Peric T; Health Science and Technologies Interdepartmental Center for Industrial Research (HST-ICIR), University of Bologna, Bologna, Emilia-Romagna, Italy.
  • Barbato O; Department of Veterinary Medicine, University of Perugia, Perugia, Italy.
  • Montillo M; Department of Food Sciences, University of Udine, Udine, Italy.
  • Rouge S; Department of Veterinary Medicine, University of Perugia, Perugia, Italy.
  • Freccero F; Department of Food Sciences, University of Udine, Udine, Italy.
Vet Rec ; 187(12): e117, 2020 Dec 19.
Article em En | MEDLINE | ID: mdl-33024010
ABSTRACT

BACKGROUND:

Adrenal gland ultrasonographic measurements are useful in clinical evaluation of patients with adrenal dysfunction in several species. In human healthy neonates, the ultrasonographic size of the adrenal glands decreases during the first days of life. Ultrasonography of adrenal glands was demonstrated to be feasible in neonatal foals. The aims of this study were to describe a technique for ultrasonographic measurement of adrenal gland size to test its reliability in neonatal foals, and to assess any variation of ultrasonographic measurements during the first five days of life in healthy foals.

METHODS:

First, measurements of the adrenal glands were retrospectively obtained by three observers in 26 adrenal gland images of 13 healthy and sick neonatal foals. The interobserver and intraobserver agreement were tested. Later, adrenal gland ultrasonographic images and measurements were acquired by one operator in 11 healthy neonatal foals at one, three and five days of life and differences among the measurements obtained at the different time points were assessed.

RESULTS:

Interobserver agreement ranged from fair to excellent (0.48-0.92), except for cortex width (<0.4); intraobserver agreement ranged from good to excellent (0.52-0.98). No significant differences were found among the measurements obtained at one, three and five days of life.

CONCLUSION:

Adrenal glands ultrasonographic measurements can be obtained consistently in equine neonates, and in contrast to people they do not vary during the first five days of life in healthy foals.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Glândulas Suprarrenais / Doenças dos Cavalos / Animais Recém-Nascidos Tipo de estudo: Diagnostic_studies Limite: Animals Idioma: En Revista: Vet Rec Ano de publicação: 2020 Tipo de documento: Article País de afiliação: Itália

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Glândulas Suprarrenais / Doenças dos Cavalos / Animais Recém-Nascidos Tipo de estudo: Diagnostic_studies Limite: Animals Idioma: En Revista: Vet Rec Ano de publicação: 2020 Tipo de documento: Article País de afiliação: Itália