Your browser doesn't support javascript.
loading
Outcomes of Current-Generation Transfemoral Balloon-Expandable Versus Self-Expandable Transcatheter Aortic Valve Replacement.
Habertheuer, Andreas; Gleason, Thomas G; Kilic, Arman; Schindler, John; Kliner, Dustin; Bianco, Valentino; Aranda-Michel, Edgar; Brown, James A; Toma, Catalin; Muluktula, Suresh; Sultan, Ibrahim.
Afiliação
  • Habertheuer A; Division of Cardiac Surgery, Department of Cardiothoracic Surgery, University of Pittsburgh, Pittsburgh, Pennsylvania.
  • Gleason TG; Division of Cardiac Surgery, Department of Cardiothoracic Surgery, University of Pittsburgh, Pittsburgh, Pennsylvania; Heart and Vascular Institute, University of Pittsburgh, Pittsburgh, Pennsylvania.
  • Kilic A; Division of Cardiac Surgery, Department of Cardiothoracic Surgery, University of Pittsburgh, Pittsburgh, Pennsylvania; Heart and Vascular Institute, University of Pittsburgh, Pittsburgh, Pennsylvania.
  • Schindler J; Heart and Vascular Institute, University of Pittsburgh, Pittsburgh, Pennsylvania.
  • Kliner D; Heart and Vascular Institute, University of Pittsburgh, Pittsburgh, Pennsylvania.
  • Bianco V; Division of Cardiac Surgery, Department of Cardiothoracic Surgery, University of Pittsburgh, Pittsburgh, Pennsylvania; Heart and Vascular Institute, University of Pittsburgh, Pittsburgh, Pennsylvania.
  • Aranda-Michel E; Division of Cardiac Surgery, Department of Cardiothoracic Surgery, University of Pittsburgh, Pittsburgh, Pennsylvania.
  • Brown JA; Division of Cardiac Surgery, Department of Cardiothoracic Surgery, University of Pittsburgh, Pittsburgh, Pennsylvania.
  • Toma C; Heart and Vascular Institute, University of Pittsburgh, Pittsburgh, Pennsylvania.
  • Muluktula S; Heart and Vascular Institute, University of Pittsburgh, Pittsburgh, Pennsylvania.
  • Sultan I; Division of Cardiac Surgery, Department of Cardiothoracic Surgery, University of Pittsburgh, Pittsburgh, Pennsylvania; Heart and Vascular Institute, University of Pittsburgh, Pittsburgh, Pennsylvania. Electronic address: sultani@upmc.edu.
Ann Thorac Surg ; 111(6): 1968-1974, 2021 06.
Article em En | MEDLINE | ID: mdl-33045207
BACKGROUND: Transcatheter aortic valve replacement (TAVR) continues to gain momentum with current-generation balloon-expandable (BE) Edwards SAPIEN 3 (Edwards Lifesciences, Irvine, CA) and self-expandable (SE) Medtronic Evolut valves (Medtronic, Minneapolis, MN). Safety and efficacy of each device has been studied independently but head-to-head comparisons remain limited. METHODS: The institutional database was used to identify patients undergoing TAVR with BE and SE systems through transfemoral access between 2015 and 2018. Patients with an alternative access were excluded. Multivariable logistic and Cox proportional hazards regression was used to compare baseline risk-adjusted 30-day Valve Academic Research Consortium-2 variables and midterm outcomes, including survival, stroke, and readmission rates. RESULTS: A total of 294 BE (52.2%) and 269 SE (47.8%) valves were implanted. BE cohort was predominantly male (59.9% vs 33.1%, P < .001), with a larger body surface area (1.9 m2 vs 1.8 m2, P < .001), fewer prior aortic valve replacements (3.7% vs 10.0%, P = .003), and a lower Society of Thoracic Surgeons predicted risk of mortality score (4.9% vs 6.7%, P < .001). After risk adjustment, SE patients had a higher propensity of ischemic stroke at 30 days (6.0% vs 1.4%, P = .015) but were comparable in other Valve Academic Research Consortium-2 variables, including mortality (1.7% vs 3.4%, P = .474), pacemaker (12.7% vs 15.2%, P = .162), and moderate paravalvular leak (1.8% vs 3.2%, P = .165). Over the midterm, SE and BE were comparable in mortality (adjusted hazard ratio [aHR], 1.24; P = .269), all-cause readmission (aHR, 0.92; P = .576), and stroke rate (aHR, 1.97; P = .061). CONCLUSIONS: Midterm outcomes of both valve types were comparable despite a higher risk of short-term stroke for the SE cohort. Select patients may benefit from one valve type over another based on clinical and anatomic risk factors.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Estenose da Valva Aórtica / Complicações Pós-Operatórias / Próteses Valvulares Cardíacas / Substituição da Valva Aórtica Transcateter Tipo de estudo: Etiology_studies / Incidence_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Limite: Aged / Aged80 / Female / Humans / Male Idioma: En Revista: Ann Thorac Surg Ano de publicação: 2021 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Estenose da Valva Aórtica / Complicações Pós-Operatórias / Próteses Valvulares Cardíacas / Substituição da Valva Aórtica Transcateter Tipo de estudo: Etiology_studies / Incidence_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Limite: Aged / Aged80 / Female / Humans / Male Idioma: En Revista: Ann Thorac Surg Ano de publicação: 2021 Tipo de documento: Article