Your browser doesn't support javascript.
loading
A Pre-implementation Study of Volumetric Modulated Arc Therapy for Same-day Planning and Treatment of Vertebral Bone Metastases Within a Rapid-access Palliative Radiotherapy Programme.
Dennis, K; Linden, K; Zohr, R; McGrath, C; MacPherson, M; Renaud, J; Granville, D; Gaudet, M; Ali, E.
Afiliação
  • Dennis K; Radiation Medicine Program, The Ottawa Hospital, Ottawa, Ontario, Canada; Division of Radiation Oncology, University of Ottawa, Ottawa, Ontario, Canada. Electronic address: krdennis@toh.ca.
  • Linden K; Radiation Medicine Program, The Ottawa Hospital, Ottawa, Ontario, Canada.
  • Zohr R; Radiation Medicine Program, The Ottawa Hospital, Ottawa, Ontario, Canada.
  • McGrath C; Radiation Medicine Program, The Ottawa Hospital, Ottawa, Ontario, Canada.
  • MacPherson M; Radiation Medicine Program, The Ottawa Hospital, Ottawa, Ontario, Canada; Division of Radiation Oncology, University of Ottawa, Ottawa, Ontario, Canada.
  • Renaud J; Radiation Medicine Program, The Ottawa Hospital, Ottawa, Ontario, Canada.
  • Granville D; Radiation Medicine Program, The Ottawa Hospital, Ottawa, Ontario, Canada.
  • Gaudet M; Radiation Medicine Program, The Ottawa Hospital, Ottawa, Ontario, Canada; Division of Radiation Oncology, University of Ottawa, Ottawa, Ontario, Canada.
  • Ali E; Radiation Medicine Program, The Ottawa Hospital, Ottawa, Ontario, Canada; Division of Radiation Oncology, University of Ottawa, Ottawa, Ontario, Canada.
Clin Oncol (R Coll Radiol) ; 33(10): 661-666, 2021 10.
Article em En | MEDLINE | ID: mdl-33980462
ABSTRACT

AIMS:

We aimed to develop a process for same-day contouring, planning, quality assurance and delivery of volumetric modulated arc therapy (VMAT) for vertebral bone metastases within our institution's rapid-access palliative radiotherapy programme. MATERIALS AND

METHODS:

Two thoracic (T6-7, T3-7) and two lumbar (L2-3, L1-5) targets were contoured on computed tomography images acquired from an anthropomorphic phantom and five patient scans. Inverse planning aimed to provide coverage of a prescribed dose of 8 Gy with a combined lung V2Gy < 25% and a combined kidney mean dose <2 Gy. Serial plans were created to identify an efficient combination of six main planning variables specific to our treatment planning system (i) voxel size (3 mm versus 5 mm), (ii) Monte Carlo statistical uncertainty (1% per calculation versus 3% per control point), (iii) fluence smoothing (medium versus high), (iv) number of iterations of segment shape changes during optimisation (1 versus 5), (v) dose calculation algorithm (Monte Carlo versus pencil beam) and (vi) number of arcs (single versus multiple). Contouring, planning, quality assurance and treatment delivery were timed.

RESULTS:

The combination of planning variables deemed efficient and appropriate was a 3 mm voxel size, statistical uncertainty of 1% per calculation, medium fluence smoothing, five iterations of segment shape changes, Monte Carlo dose calculation and single full arc delivery. Patient scan contouring times ranged from 7 to 9 min (T6-7), 11-13 min (T3-7), 5-7 min (L2-3) and 8-10 min (L1-5) and planning times ranged from 9 to 15 min (T6-7), 13-25 min (T3-7), 18-25 min (L2-3) and 21-31 min (L1-5). Physics quality assurance times ranged from 15 to 21 min and beam-on times ranged from 3 to 6 min.

CONCLUSIONS:

The combined elements of VMAT for thoracic and lumbar vertebral bone metastases were completed in under 2 h. This new process makes same-day contouring, planning, quality assurance and treatment delivery of VMAT feasible within our rapid-access palliative radiotherapy programme.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Radiocirurgia / Radioterapia de Intensidade Modulada Tipo de estudo: Health_economic_evaluation / Prognostic_studies / Sysrev_observational_studies Limite: Humans Idioma: En Revista: Clin Oncol (R Coll Radiol) Assunto da revista: NEOPLASIAS Ano de publicação: 2021 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Radiocirurgia / Radioterapia de Intensidade Modulada Tipo de estudo: Health_economic_evaluation / Prognostic_studies / Sysrev_observational_studies Limite: Humans Idioma: En Revista: Clin Oncol (R Coll Radiol) Assunto da revista: NEOPLASIAS Ano de publicação: 2021 Tipo de documento: Article